Doc 01-18540 

Page 1 of 4

 

 

Estate Series Gate Operators - X1 Board 

CPU

 

Replacement Instructions

 

 
Follow the instructions below to replace the ESTATE Controller 
processor chip with the new version (p/n 29-X1-090). 

REMOVING THE EXISTING CHIP 

Remove gate operator cover (or access door) to access 
controller board. 

Verify that you will be installing the new chip to the Controller 
Board SN1110073 (see Figure 1). 

3 IMPORTANT:

 Enter programming mode and manually 

record all the current gate operator settings onto the 
Programming Menu table on page 2.  

You must have these 

settings to re-enter after installing the new chip.

 

SGOWin Users: 

Instead of manually recording the 

operator’s settings, connect to the unit and perform a 
“Receive All” command.  Refer to the 

SGOWin User’s Guide

 

(p/n 01-20293). 

4  TURN OFF POWER TO OPERATOR

.

 

Use the supplied chip-puller (Philmore p/n 10270) to remove 
old chip.

  

Insert the chip puller’s hooks into the socket’s 

corner slots, center the puller, and gently squeeze it to 
extract the chip.

  TIP:

 To avoid damaging the chip or socket, 

keep the puller centered over the chip and lift it straight out 
of the socket. 

INSERTING THE NEW CHIP 

Carefully insert the ESTATE controller’s CPU into the 
receptacle according to Figure 2. 

Ensure that ALL of the pins are aligned with the slots around 
the edges of the socket. 

Gently, yet firmly, press down on the center of the chip until 
it reaches the bottom of the socket. 

Turn ON power to the operator.  Wait approx. 5 seconds. 

 

If the board’s 7-segment LED spells out “HELLO” (letter 
by letter), you have 

correctly

 

inserted

 the chip. 

If it spells out “NO FID”, you have a bad chip.  Return 
the bad chip to LiftMaster and insert a new chip. 

 

If the board’s 7-segment  LED does not emit a light, you 
may have 

incorrectly

 inserted

 the chip.  Cycle power 

a few times to be sure and then go to step 4 (under 
Removing the Existing Chip) and follow the instructions 
again to remove and reinstall the chip. 

4 IMPORTANT:

 Enter programming mode and manually enter 

all the gate operator settings you recorded on the 
Programming Menu table (page 2). 

SGOWin Users: 

Instead of manually entering all the 

operator’s settings, connect to the unit and perform a “Send 
All” command.  Refer to the 

SGOWin User’s Guide

 (p/n 01-

20293).  

NOTE:

 For Master/Slave configurations, you MUST 

manually program the Operator Type for each operator (see 
Step 02 on the Programming Menu table - page 2). 

 

 

 

 

 

 

 

 

 

 

Figure 1: X1 Board 

 

Chip Receptacle

Match arrows

when inserting

new chip.

New X1 Chip

Liftmaster

06-X1-

FID# _______

rev

When removing old chip,

insert chip puller hooks here.

 

Figure 2: Removing/Inserting the X1 Chip 

TEST the full functionality of all the 
operator’s accessories/inputs (e.g., loops, 
photo eyes, etc.).  Refer to the operator’s 

Installation Instructions

 for more information. 

Replace operator cover (or access door). 

 

 

To avoid serious BODILY INJURY or damage 
to the operator: 

 

TURN OFF power at the power switch 
before servicing the operator. 

 

GROUND YOURSELF thoroughly before 
handling the circuit board.  Grounding 
methods include touching a cold, grounded 
metallic pipe or using a grounding strap. 

    WARNING

 

7-Segment 

LED 

Chip 

Receptacle 

Verify Board 

Number Here 

(SN1110073) 

Содержание Estate Series X1 LiftMaster Professional

Страница 1: ... If the board s 7 segment LED spells out HELLO letter by letter you have correctly inserted the chip If it spells out NO FID you have a bad chip Return the bad chip to LiftMaster and insert a new chip If the board s 7 segment LED does not emit a light you may have incorrectly inserted the chip Cycle power a few times to be sure and then go to step 4 under Removing the Existing Chip and follow the ...

Страница 2: ...rrupt Bar Backup If Closing Up to 3 0 499 in inches 14 Interrupt Bar Backup If Opening Up to 3 0 499 in inches 15 Return Factory Set Defaults 6 101010 Partial default reset all except steps 24 26 28 34 and 36 191919 Full default reset 17 Change Password 6 Any combination of 6 digits 18 Verify Password 6 User designated password 19 Set Date And Time 11 with 2 more optional for seconds YYMMDDdhhmm s...

Страница 3: ... 0 Ignore if date falls on holiday 1 Use if date falls on holiday 2 Use day 8 if date falls on holiday 39 Reset Unit Must enter 101010 101010 resets unit 40 Alert Modem Phone Number Up to 16 Maximum of 16 digits 00 erases digits 41 Alert Call Schedule NOTE HHMM start call time hhmm end call time 11 digits dsHHMMhhmmo d One digit week day 1 Sun 7 Sat 8 Holiday s One digit for segment s 1 or 2 HH Tw...

Страница 4: ...uch information may not be distributed without the prior written consent of LiftMaster The software and firmware included in the LiftMaster product as they relate to this documentation are also protected by copyright and contain information proprietary to LiftMaster FOR TECHNICAL SUPPORT OR TO ORDER REPLACEMENT PARTS CALL OUR TOLL FREE NUMBER 800 528 2806 Tucson AZ Monday thru Friday 5 AM 6 PM Sat...

Отзывы: