Rev E
Doc 01-20201
12 of 33
BIPARTING BARRIER GATES
Figure 8. Biparting Barrier Gates Photo-Sensor Layout.
WARNING
Buy only UL-approved photo-sensors made for use with vehicular gate
operators or system. Otherwise, safe gate operation may be compromised.
IMPORTANT NOTE:
The installation shown in Figure 8 above is a suggested layout using emitters and
receivers. Any UL-approved photo-sensors are acceptable,
but they must cover the entire area of
gate travel to be effective.
Install photo-sensors in three
Coverage Areas
as shown in Figure 8.
1.
Coverage Area A
- Inside-Open Coverage:
not needed in barrier gate installation.
2.
Coverage Area B
- Inside-Closed Coverage:
Install one photo-sensor: Inside the fince line, from the Master gate operator to the Slave gate
operator.
3.
Coverage Area C
- Outside-Closed Coverage:
Install one photo-sensor: Outside the fence line, from one fence edge to the other.
4. Connect the photo-sensors to whichever unit is most convenient. For wiring instructions, see
Section C, Connecting Input Wiring, below.
B. PHOTO-SENSOR INSTALLATION FOR TRAP/TANDEM GATE CONFIGURATION
Photo-sensors must be installed on each gate separately. For instructions see the Installation and
Operation Manual for the gates.