background image

en-8

DESCRIPTION OF PUSH BUTTONS

P1 button to program “simple” mode

P2 button to program “individual” mode

P3 button to program “Timer to close”

Description of LED’s (light-emitting diode)

Description 

Colour

Function

STOP/8.2KOhms green

monitors emergency switch 

or safety edge

ON: blocks control board

OFF: OK

“Key symbol”

red

key switch

ON: key switch is operating

OFF: key switch is not 

operating

PHO2

red

Photocells 2

ON: OK (active)

OFF: no photocell fitted

PHO1

red

Photocells 1

ON: OK  (active)

OFF: no photocell fitted

LEARN

yellow

learn mode indication

ON: learn mode active

OFF: learn mode inactive

DIAGNOSTIC

red

diagnosis mode

Refer to FAQ’s

DESCRIPTION

FUNCTION

L

Connector L 230V supply

N

Connector N 230V supply

Battery

Connector for a battery kit +/-

475E + 041ADBL-0115

Motor MASTER

motor 1 (master opens first)

Motor SECOND

motor 2 (Second opens second)

24V/150mA

Flashing light (accessory)

MASTER

Motor1

BRN

brown cable

GRN

green cable

WHT

white cable

YEL

yellow cable

SECOND

Motor2

BRN

brown cable

GRN

green cable

WHT

white cable

YEL

yellow cable

“Key symbol”

key switch

COM

negative pole

PHOTO1

Photocells 1

PHOTO2

Photocells 2

COM

negative pole

STOP 8.2KOhms

connector for emergency switch or 

safety edge with 8.2KOhms

RADIO

connection for 801719 radio receiver

E-lock symbol

connection for E-lock control board

INPUT 24VAC

24V power input from transformer. 

Can be connected with any polarity.

Transformer 230VAC

230V supply to transformer. Can be 

connected with any polarity.

250V/2A

Fuse 250V/2A (2x included)

Only modify settings when control bord

is disconnected. Otherwise modifications will

not be accepted!!!

Intelligent Security & Fire Ltd.

Содержание ART200K

Страница 1: ...lectrical installation codes Power cables must only be connected to a properly earthed supply Any entrapment possibility by the moving wing between wing walls must be secured with safety edges or IR s...

Страница 2: ...again Outside temperature and gate represent important parameters for actual operating duration AVAILABLE INSTALLATION ACCESSORIES 1 041ASWG 0482 50 50m roll of installation cable 6 pole for outdoor u...

Страница 3: ...einforced additionally as they do not withstand the strain otherwise GATE CONFIGURATION The ART is suitable for use with wide pillars up to about 30cm in width The amount of room around the pier affec...

Страница 4: ...side and inside of the gate in order to prevent wood from giving and the connection to become loose Thin wooden gates without metal frame must be reinforced additionally as they do not withstand the s...

Страница 5: ...x 45 switch fully pushed cam operates switch Gate open switch free 4 TYPICAL CONFIGURATION OF A UNIT 1 Motor 2 Control board 3 Photocell active for closing max height 200 mm First photocell 4 photocel...

Страница 6: ...uired distances and establishing correct position of drill holes Hardware not included B Fasten baseplate for transformer in casing Screws 3 5 x 9 5mm C Fasten transformer on to baseplate do this usin...

Страница 7: ...ROL SUMMARY a start with still dead 230Volts supply cable on the left side of the box b Attach cable eye to ground wire Then connect ground wire to base plate with washer and nut exactly as shown in p...

Страница 8: ...for a battery kit 475E 041ADBL 0115 Motor MASTER motor 1 master opens first Motor SECOND motor 2 Second opens second 24V 150mA Flashing light accessory MASTER Motor1 BRN brown cable GRN green cable WH...

Страница 9: ...n failsafe photocell must be installed The Chamberlain failsafe system 2 cable system has small LEDs light that can be seen from the outside on both sides to indicate the status of the photocell Diagn...

Страница 10: ...gate may work improperly Redo programming if required DELETE Press learn buttons CH1 or CH2 for approx 10 seconds until LED goes out All codes programmed to this channel are deleted 1 2 Motor 1 or 2 m...

Страница 11: ...for approx 2 3 seconds until yellow LED flashes 2 Monitor the gate Press and hold P1 for 1 2 seconds The wing with motor 1 opens If motor 1 closes it is wired incorrectly and the red and blue wires of...

Страница 12: ...re possible Activate 1 Press and hold P2 until yellow LED starts flashing 2 Now count the time you wish to program 3 Press P2 again Done Deactivate 1 Press and hold P2 until yellow LED starts flashing...

Страница 13: ...if gate can be easily moved C Gate stopped through windload C Do not operate gate by windstorm D Reprogram travel to achieve sufficient level of fo 7x blinking Photocells 1 block installation A Objec...

Страница 14: ...not connected properly 1 Programming remote control 2 Find and rectify fault s see description of LEDs 3 Check photocell connection programming 4 Check terminals and connections Control board does not...

Отзывы: