Chapter 2.2 - Key Function

   /   08

Chapter 2.2 - Key Function

   /   07

2.2.2  Power Meter

PM button has 2 options ‘Auto’ 
and ‘Manual’ . Designated by 
“A” and “M” in top right of 
screen . If you select ‘Auto’, the 
instrument automatically scans 
the optical input and displays 
the fiber with the highest level 
of power .

If “Manual” is selected, the user selects the fiber to be measured .

Press the                 button, mode will change between “Auto” and “Manual” and 
vice versa .

You can select the different fibers using 

Press the               button to change the inspection wavelength .

5     jkl

8     tuv

PM

1     .qz

λ

2     abc

2.2.3  Scan

Press the               button, scan-
ning starts for all 12 Fibers .

Press the               button to 
change the inspection 
wavelength . .

2.2.4  dB / dBm: Relative/Absolute Measurements

This button toggles between  
dB (relative) & dBm (absolute) 
power measurements

To measure the relative loss of 
an MPO circuit, connect the 
CO-OPM-MPO12 to a known 
light source with a short (test) 
jumper .

(continued)

SCAN

3     def

dB/dBm

4     ghi

λ

2     abc

Содержание CO-OPM-MPO12

Страница 1: ...1 5 Meter Care 4 2 0 Getting Started 5 2 1 Explanation of Operating Keys 5 2 2 Key Function 6 2 2 1 Power ON OFF 6 2 2 2 Power Meter 7 2 2 3 Scan 8 2 2 4 dB dBm Relative Absolute Measurements 8 2 2 5...

Страница 2: ...nnector MPO Angled unpinned Display Units dB dBm Display 2 8 TFT LCD 16 bit Color Battery Power Rechargeable Lithium Polymer 7 hr Operating Temperature 20 55 C Weight 13 oz Dimensions h w d 7 x 3 25 x...

Страница 3: ...e scanned and power levels are displayed dB dBm Toggle between dB and dBm UOM Move UP in a menu page up in result screen Graph Power levels of all fibers are displayed as a graph Recall Recall saved m...

Страница 4: ...If Manual is selected the user selects the fiber to be measured Press the button mode will change between Auto and Manual and vice versa You can select the different fibers using Press the button to...

Страница 5: ...res the power measurements A scan will appear with dB values close to 0 00 dB A graph is also available Remove test jumper and replace with jumper to be measured Press scan The relative loss of the ju...

Страница 6: ...s the user to save a measurement The following message shows and the measurement is saved using the current date and time as the filename Then press the button to save To abort saving press ESC ENTER...

Страница 7: ...ged with the and buttons after offset value is entered 5 jkl 8 tuv 2 3 1 Polarity Use this option to change the polarity of the measurement Straight Type A Rollover Type B Flipped Type C 2 3 3 Auto Po...

Страница 8: ...he data you want to delete the message appears on the screen to confirm to delete or not Press the button to delete measurement from the memory ENTER ENTER ENTER 5 jkl 8 tuv 2 3 6 Data Format You can...

Страница 9: ...s If you choose Measured only active fibers will be displayed 5 jkl 8 tuv 2 3 8 Scan type This option allows the user to choose the scan type Press Scan Single or Real Time using the and keys user can...