background image

3

Содержание Corvec SH12

Страница 1: ...chaffsteaux ltd chaffoteaux et Maury m SHE installati servicing instructions ...

Страница 2: ...mended in the appro priate section of these instructions The installation of the shower heater must be in accordance with the relevant requirements of the Gas Safety Regulations Building Regulations and the Byelaws of the local Water Undertaking It should be in accordance also with any relevant requirements of the local gasregion and local autho rity and the relevant recommendations of the followi...

Страница 3: ...t operation of the heater only An additional allowance must be made for the resistance of the shower and associatedpipework and fittings This should be apprM mately O 2bar 3 1b in2 Water j 1 Right hand 15 mm copper connection Water outlet Left hand 15 mm copper connection Gas Centre 15 mm copper connection Height 23 6 ius 600 mm Width 10 5 ins 267 mm Depth 210 mm 8 25 ins Weight 10 7 kg 23 5 lbs S...

Страница 4: ...liner through the wall ensuring that it is horizontal and that the flanged end is flush with the face of the wall Trim to length if necessary so that the outer end of the liner is level with the face of the outside wall Make good around the wall liner fig 1 FITTING THE TERMINAL The terminal is fitted from the outside of the building by fixing the two spring loaded chains over the hooks on the insi...

Страница 5: ...ndness Fit the gas control knob and light the pilot by turning 90 anti clockwise It may be necessary to wait for the pilot to purge if so wait a few moments then turn to the off position and repeat Turn the gas control fully anti clockwise to the main gasposition Turn on the shower the heater will now light Handset holder and bracket Hose and washers Check for gas soundness around heater gas compo...

Страница 6: ...order do not forget to replace the skirt fixing screw and reinforcing strip 4 Pilot unscrew the pilot tube clamping screw A fig 7 and remove the clamp and tube Blow through the tube to remove any dust Remove the burner seesection 2 Unscrew the knurled pilot burner outer ring A fig 7 Unscrew the pilot body B with a 15 mm spanner It may be necessary to remove the heating body Clean by blowing or was...

Страница 7: ...eplace in reverseorder Fig 9 11 GasFilter fg 11 A gas filter is fitted between the gas service tap and the heater To clean turn off the gasat the servicetap Unscrew the union nut attaching the tap to the heater Lower the union nut and withdraw the filter which also acts asa washer Clean the filter by blowing or washing in water do not use solvents since the filter is made of nylon and may disolve ...

Страница 8: ...heater Refit Check sealing Check working pressureat meter Check water governor Replace Fit Mi4IN BURNER DOES NOT LIGHT MAIN BURNER i Gasservice tap not open fully i i Gaspressurelow i i i Water rate low i v Gasvalve push rod jammed v Diaphragm punctured vi Venturi blocked or loose v i i Gas control tap faulty v i i i Injector size Open fully Check at manifold and at inlet with heater running Check...

Страница 9: ...IENT WATER FLOW i Water servicetap partly closed i i Blocked venturi i ii Low water pressure i v Water governor faulty v Water governor sticking v i Foreign matter m water section HEATER SMELLS FROM INSIDE BUILDING HEATER SMELLS FROM OUTSIDE BUILDING AT POINT OF TERMINATION 1 HIGH WATER FLOW i Appliance newness i i Heater casenot fitted correctly i i i Defective sealingaround heater case i Gasrate...

Страница 10: ... Knob GasketWallLmertoRearCase WallFixingScrew Wall Fixing Stud NutM7 Washer GasService Tap GasFilter Copper Tail Nut Washer Adaptor Bend for Top Outlet Thermocouple Assembly Electrode Lead Assembly Diaphragm No MARKERS OFF PART No 1 38741 1 36246 1 36732 1 29091 2 25617 2 5787 2 29094 4 5369 1 31281 1 37309 1 20677 1 20747 14 1 22835114 1 26103 1 35087 1 34239 1 18197 30 CHAFFOTEAUX LIMITED Conco...

Страница 11: ...ESP002 ...

Отзывы: