4

Heating 
1)Turn the CH thermostat clockwise 17.

2) If the room thermostat (if fitted), the
boiler temperature control 

and the

clock (if fitted) are all calling for heat, the
orange "burner on" indicator 

21 will

light and the heating will be on.

When there is a need for hot water while

the heating is on, it is only necessary to

turn on a hot tap. The heating will be

interrupted momentarily while the hot

water is being delivered. The boiler will

switch back automatically to heating when

the tap is turned off.

Note: if the boiler has been push off for

some time the first attempt to light it may

result in a lockout 

. If this happens

press the reset button 20 and the boiler

will light.

To put Boiler Off Completely

1) Push the on/off button 15 and the light

is off. 

2) Turn the gas tap Fig. 2 OFF.

Domestic Hot Water Mode

In order to supply hot water, the main

switch 15 Fig. 4 must be in ON position I

This will be confirmed by the green light

15

Fig. 4. Turn the selector switch 16

clock .

When a tap or shower is turned on, the

flow of mains water, above 2 litres per

min., will activate the 3 way valve 22 Fig. 5

to move to the DHW position. 

The pump will now circulate primary water

heated by the main heat exchanger

through the secondary heat exchanger.

The gas valve 13 Fig. 5 open to allow gas

to the burner. The ignition sequence

begins and a continuous high speed spark

ignites the gas. As soon as a flame is

detected the orange indicator bulb 

21

Fig. 4 will light and the modulating

solenoid opens to allow the full gas rate. If

a flame is not detected, after 8 seconds,

the security solenoids close and shut off

the gas. The red lockout indicator bulb 

20 Fig. 4 will show. The domestic hot

water temperature is controlled by the

flow and return control thermistor 9- 10

Fig.5. This system anticipates the

changes of temperature in the secondary

heat exchanger and ensures accurate

temperature regulation. 

When the tap is closed the burner is

extinguished and the pump stops.

Priority will be given to a demand for hot

water. This will interrupt the central

heating for the duration of hot water

delivery.

Central Heating Mode

To be able to supply heating, the main

button 15 Fig. 4 must be in position. This

will be confirmed by the green  light. 

Turn the selector switch 17 clock. 

When there is a demand for heating

(either from the room thermostat or the

clock) and the boiler temperature control

is calling for heat. The pump starts

allowing the ignition sequence to begin. 

The gas valve 13 Fig. 5 open to allow

gas to the burner. The ignition sequence

begins and a continuous high speed

spark ignites the gas. As soon as a

flame is detected the orange indicator

bulb 

21 Fig. 4 will light. After 45

seconds the modulating solenoid opens

to allow the full gas rate. If a flame is not

detected, after 8 seconds, the security

solenoids close and shut off the gas. The

red lockout indicator bulb 

20 Fig. 4

will show.

The central heating flow temperature is

controlled by the central heating control

thermistor Fig. 5. The boiler has been

designed to minimise cycling and will not

attempt to relight for 3 minutes after the

boiler thermostat has been satisfied (it is

possible to reduce the time to 30 s if

necessary). When the room thermostat

is satisfied the burner will switch off and

the pump will remain running for a

further 3 minutes before it stops.

NB : it is possible to override the 3 minute

delay by putting off and on the central

heating selector switch 17.

WIRING 

DIAGRAM

Содержание MINIMA MX2 24 FF NG

Страница 1: ...orking pressure 0 1 bar Maximum DHW working pressure 10 bar Gas category II 2H 3 Nominal gas flow rate at 15 C and 1013 mbar MX2 24 MX2 30 Maximum Minimum Maximum Minimum power 24 kW power 10 kW power 30 kW power 10 kW Natural gas G 20 at 20 mbar 2 76 m3 h 1 27 m3 h 3 41 m3 h 1 27 m3 h Butane gas G 30 at 28 mbar 2 06 kg h 0 94 kg h 2 50 kg h 0 94 kg h Propane gas G 31 at 37 mbar 2 02 kg h 0 93 kg ...

Страница 2: ...rode 28 Ignition electrode 29 Main heat exchanger 30 Water water heat exchanger 31 DHW flow sensor 32 Combustion chamber made of aluminium coated steel with 4 ceramic fibre panels to insure heat insulation 33 Right hydraulic assy 34 Left hydraulic assy 35 Single speed pump 36 Automatic air separator and automatic vent 37 Automatic by pass 38 Flue hood with fan 39 Air Pressure switch 40 Flue sampli...

Страница 3: ...pressure gauge 18 3 Open the gas tap 3 4 The boiler is now ready to use 5 Push on the knob 15 The knob 15 power on will light Hot Water 1 Turn the DHW thermostat clockwise 16 2 Turn on a hot water tap the orange burner on indicator will light 21 and the water will become hot Control panel MX2 FUNCTIONAL DIAGRAM 39 8 29 32 24 36 35 14 11 38 34 12 22 33 10 25 28 26 30 15 20 17 16 18 19 21 Fig 3 Fig ...

Страница 4: ...f the gas The red lockout indicator bulb 20 Fig 4 will show The domestic hot water temperature is controlled by the flow and return control thermistor 9 10 Fig 5 This system anticipates the changes of temperature in the secondary heat exchanger and ensures accurate temperature regulation When the tap is closed the burner is extinguished and the pump stops Priority will be given to a demand for hot...

Страница 5: ... in the flue turret SUGGESTED SEQUENCE for SERVICING Before disconnecting or removing any parts isolate the gas and electricity supplies Ensure that the appliance is cool for detail please see section on Parts Removal and Replacement Preliminary Checks Remove outer case Check the system pressure is at least 0 8 bar cold Check operation of solenoids Check that the burner is extinguished fully when ...

Страница 6: ...Remove the clip securing the water brass inlet connection Remove the brass connection and the DHW flow switch plunger Reassemble in the reverse order take care to the wise 10 Pressure Switch Carry out step 1 Disconnect the wire from the pressure switch Disconnect the two pressure pipes Remove the T20 upper screws securing the pressure switch from the chassis 11 DHW Reed Relay Carry out step 1 Disc...

Страница 7: ...rol board and earth plug from earth socket Unscrew the pump nut F of the flow pipe from the volute Remove the clip H on the pump volute and pull the pump toward you Reassemble in reverse order 17 Pressure relief valve Drain the boiler first remove the clip securing the valve and pull it toward you Remove in reverse order take care to the valve positionning 18 NTC and Overheat thermostat Remove the...

Страница 8: ...Supplied By www heating spares co Tel 0161 620 6677 8 FAULT FINDING CHART ...

Страница 9: ...Supplied By www heating spares co Tel 0161 620 6677 9 ...

Страница 10: ...Supplied By www heating spares co Tel 0161 620 6677 10 ...

Страница 11: ...Supplied By www heating spares co Tel 0161 620 6677 11 ...

Страница 12: ...m m Primary water circulation defect m m l m l l Central heating inlet thermistor faulty open circuit m m l l m m Central heating inlet thermistor faulty short circuit m m l l m l Central heating oulet thermistor faulty open circuit m m l l l m Central heating oulet thermistor faulty short circuit m l m m l m Firing problem m l m l m m Wiring problem or fuse 1 25 A m l m l m l Fan on but does not ...

Страница 13: ...06 VALVE KIT 61311597 537 PRESSURE RELIEF VALVE 61312668 538 PUMP AIR SEPARATOR 15 50 61312183 PUMP AIR SEPARATOR 15 60 61313464 541 THERMISTOR TEMP SENSOR 61000733 543 STOPPED WATER THROTTLE 61311745 589 WATER WATER HEAT EXCHANGER 61302409 615 PRINTED CIRCUIT BOARD PRINC 65100774 616 PRINTED CIRCUIT BOARD AFF 65100773 622 IGNITION PUSH ROD 61312414 649 PRESSURE GAUGE 61313561 650 WHITE KNOB 61312...

Страница 14: ...without prior notice and accepts no liability for any errors or omission in the information contained in this document Manufacturer Chaffoteaux Maury France Commercial subsidiary M T S GB Limited MTS Building Hughenden Avenue High Wycombe Bucks HP13 5FT Telephone 01494 755600 Fax 01494 459775 internet www chaffoteaux co uk E mail info mtsgb ltd uk Technical Support Help Line 01952 222288 ...

Отзывы: