44
Menu - 6 - External Sensor Settings
DISPLAY
ACTION
CONFIGURATION
once
x times
F
a
c
to
ry
s
e
tt
in
g
Section
Digit 1 Digit 2
Digit 3 and 4
External Sensor Fitted
6
0
0
: External sensor fitted
1
: No external sensor
(factory setting)
Automatic heating
adjustment active
6
1
0
: Inactive - External Sensor not
fitted (factory setting)
1
: Active - External Sensor fitted
Thermal Curve
(see table
D
)
6
2
0.3
0.5
1
1.2
1.5
2
2.5
3
Parallel Shift
(see table
E
)
6
3
from
0
to
20
(in steps of 1)
In the event of connection of the external sensor, you must:
1.
Activate the external senor (menu 6.0)
2.
Activate the automatic heating adjustment (menu 6.1)
3.
Select the correct thermal curve (menu 6.2)
4.
Adjust the parallel shift (menu 6.3)
N
OTE
:
S
EE
S
ECTIONS
14.6, 14.7
AND
14.8 (
PAGES
33 & 34)
FOR INSTRUCTIONS ON SETTING THE ABOVE
.