Страница 1: ...perating Instruction Manual Please read these instructions carefully before installation use and retain them for future reference LP GAS VFSL1200 These appliances conform to the requirements of SANS 1...

Страница 2: ...S T Y LE SAF E T Y Q U A LITY THAT L A S T S CONGRATULATIONS o n y o u r p u r c h a s e o f a CHAD O CHEF Fireplace a n d W E L C O M E t o t h e CHAD O CHEF family...

Страница 3: ...ATION REQUIREMENTS 2 INSTALLATION INSTRUCTIONS 3 FOR QUALIFIED GAS INSTALLER 3 NG6801 VALVE Operating Instructions 4 NG6801 VALVE Pressure Testing 4 Checklist For Gas Installer 5 Caution 5 Warnings 6...

Страница 4: ...ations It is the installer s responsibility to do these calculations on behalf of the home owner 6 This appliance may only be installed by a registered LP Gas installer and must comply with the instal...

Страница 5: ...bedrooms or bathrooms where the humidity levels are too high See page 1 Avoid areas where there are strong draughts which may be generated by outside doors It is recommend that the fireplace should n...

Страница 6: ...Connect up according to SANS 10087 1 Connect a copper pipe from the gas bottle via a regulator complying with SANS 1237 to the 8 compression fitting on the control valve taking into account the distan...

Страница 7: ...hed during use wait 3 minutes before repeating the ignition procedure 5 Continue turning the knob anticlockwise to the HIGH position and the main burner should light after a few seconds 6 Select the r...

Страница 8: ...re glass pebbles than recommended and supplied See Page 2 The room must be bigger than the minimum room size for that fireplace See Page 2 Ensure that there is adequate ventilation in the box housing...

Страница 9: ...WARNING CARBON MONOXIDE POISONING CAN LEAD TO DEATH Carbon monoxide poidoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the...

Страница 10: ...of malfunction and at least once in 2 years Spiders are the biggest pests because they tend to occupy the smallest of holes which will be in the burner venturi or the pilot air holes If spiders are a...

Страница 11: ...Guarantee Claim Form...

Страница 12: ...Manufactured By Chad o Engineering PO Box 986 Honeydew 2040 Tel 011 668 1910 Email Sales chad o chef co za www chad o chef co za...