5. Parameters Setting Method
Example: Please short-cut terminal 15 & 17 and open terminal 15 & 16
Step 1. Press MODE button
PRG blink
01
0004
Step 2. Press
▲
or
▼
button to modify value
PRG blink
01
0005
Step 3. Press SET button to confirm the value modification finished.
000.0
100.0
Accomplishing setting, system will return to normal display operation after a
few seconds. If you need to modify other parameters, please repeat the
procedure above. Press MODE button on and on, the red LED will display
parameters 01~07 in a circle.
6.Function: Parameters Table
Parameter
No.
Function Range
Factory
Setting
User
Setting
01
406s function selection
0-31
8
02 Response
time
1-99
30
03
Time adjust for speed up
and down
1-99 30
04
Ratio “K” for main speed 100-9999
1000
05
Linear speed “K”
100-9999
1000
06
Upper limit of speed
0-9999
1000
07
*
Additional
(Voltage per start)
0-255 30
*
If the setting is 30, the result is 3 second.
Higher of the value of parameter 02 and 03 results slower response time.
Parameter 04, 05 and 06 have to modify depending on actual situation.
EMAIL:[email protected]
Http://www.ch-sys.com