APPENDIX A - THERMISTOR TEMPERATURE DERIVATION

 

 

Thermistor Type: YSI 44005, Dale #1C3001-B3, Alpha #13A3001-B3 

 

Resistance to Temperature Equation: 

T

A B LnR

C LnR

1

273 2

3

(

)

(

)

.

 

 

Equation B-1  Convert Thermistor Resistance to Temperature 

 
Where: 

 Temperature in 

C. 

 

LnR 

 Natural Log of Thermistor Resistance 

 

 1.4051 

 10

-3

 (coefficients calculated over the 

50 to +150

 C. span) 

 

 2.369 

 10

-4

  

 

 1.019 

 10

-7

  

 

Ohms 

Temp 

Ohms 

Temp 

Ohms 

Temp 

Ohms 

Temp 

Ohms 

Temp  

201.1K 

-50 

16.60K 

-10 

2417 

30 

525.4 

70 

153.2 

110 

187.3K 

-49 

15.72K 

-9 

2317 

31 

507.8 

71 

149.0 

111 

174.5K 

-48 

14.90K 

-8 

2221 

32 

490.9 

72 

145.0 

112 

162.7K 

-47 

14.12K 

-7 

2130 

33 

474.7 

73 

141.1 

113 

151.7K 

-46 

13.39K 

-6 

2042 

34 

459.0 

74 

137.2 

114 

141.6K 

-45 

12.70K 

-5 

1959 

35 

444.0 

75 

133.6 

115 

132.2K 

-44 

12.05K 

-4 

1880 

36 

429.5 

76 

130.0 

116 

123.5K 

-43 

11.44K 

-3 

1805 

37 

415.6 

77 

126.5 

117 

115.4K 

-42 

10.86K 

-2 

1733 

38 

402.2 

78 

123.2 

118 

107.9K 

-41 

10.31K 

-1 

1664 

39 

389.3 

79 

119.9 

119 

101.0K 

-40 

9796 

1598 

40 

376.9 

80 

116.8 

120 

94.48K 

-39 

9310 

1535 

41 

364.9 

81 

113.8 

121 

88.46K 

-38 

8851 

1475 

42 

353.4 

82 

110.8 

122 

82.87K 

-37 

8417 

1418 

43 

342.2 

83 

107.9 

123 

77.66K 

-36 

8006 

1363 

44 

331.5 

84 

105.2 

124 

72.81K 

-35 

7618 

1310 

45 

321.2 

85 

102.5 

125 

68.30K 

-34 

7252 

1260 

46 

311.3 

86 

99.9 

126 

64.09K 

-33 

6905 

1212 

47 

301.7 

87 

97.3 

127 

60.17K 

-32 

6576 

1167 

48 

292.4 

88 

94.9 

128 

56.51K 

-31 

6265 

1123 

49 

283.5 

89 

92.5 

129 

53.10K 

-30 

5971 

10 

1081 

50 

274.9 

90 

90.2 

130 

49.91K 

-29 

5692 

11 

1040 

51 

266.6 

91 

87.9 

131 

46.94K 

-28 

5427 

12 

1002 

52 

258.6 

92 

85.7 

132 

44.16K 

-27 

5177 

13 

965.0 

53 

250.9 

93 

83.6 

133 

41.56K 

-26 

4939 

14 

929.6 

54 

243.4 

94 

81.6 

134 

39.13K 

-25 

4714 

15 

895.8 

55 

236.2 

95 

79.6 

135 

36.86K 

-24 

4500 

16 

863.3 

56 

229.3 

96 

77.6 

136 

34.73K 

-23 

4297 

17 

832.2 

57 

222.6 

97 

75.8 

137 

32.74K 

-22 

4105 

18 

802.3 

58 

216.1 

98 

73.9 

138 

30.87K 

-21 

3922 

19 

773.7 

59 

209.8 

99 

72.2 

139 

29.13K 

-20 

3748 

20 

746.3 

60 

203.8 

100 

70.4 

140 

27.49K 

-19 

3583 

21 

719.9 

61 

197.9 

101 

68.8 

141 

25.95K 

-18 

3426 

22 

694.7 

62 

192.2 

102 

67.1 

142 

24.51K 

-17 

3277 

23 

670.4 

63 

186.8 

103 

65.5 

143 

23.16K 

-16 

3135 

24 

647.1 

64 

181.5 

104 

64.0 

144 

21.89K 

-15 

3000 

25 

624.7 

65 

176.4 

105 

62.5 

145 

20.70K 

-14 

2872 

26 

603.3 

66 

171.4 

106 

61.1 

146 

19.58K 

-13 

2750 

27 

582.6 

67 

166.7 

107 

59.6 

147 

18.52K 

-12 

2633 

28 

562.8 

68 

162.0 

108 

58.3 

148 

17.53K 

-11 

2523 

29 

543.7 

69 

157.6 

109 

56.8 

149 

 

 

 

 

 

 

 

 

55.6 

150 

 

Table A-1  Thermistor Resistance versus Temperature 

Содержание CGEO-CR

Страница 1: ...CGEO INTERNATIONAL LIMITED Model CGEO CR Vibrating Wire Crackmeter Installation Manual...

Страница 2: ...ors 5 2 2 3 Installation using Machine Bolt Expansion Anchors 6 2 3 Cable Installation 7 2 4 Electrical Noise 7 2 5 Lightning Protection 7 3 TAKING READINGS 8 3 1 Operation of the CGEO PR VW Readout B...

Страница 3: ...ibrating wire element The tension in the wire is directly proportional to the extension hence the opening of the joint can be determined very accurately by measuring the strain change with the vibrati...

Страница 4: ...rts upon requirement 75 mm 10mm Thread Figure 3 Standard Grouting Anchor Rod When setting the gage position using a portable readout see section 3 use the ranges in Table 2 to determine the proper pos...

Страница 5: ...e reading with a portable readout Use Table 2 or the readings on the calibration sheet to check the position Installation complete Note Under normal circumstance the installation of transducer itself...

Страница 6: ...tion complete 2 2 3 Installation using Machine Bolt Expansion Anchors The Bolt Expansion Anchor is needed to customize applied to quick installation or unable to install groutable anchor The user self...

Страница 7: ...tection The Vibrating Wire Crackmeter unlike numerous other types of instrumentation available from CGEO do not have any integral lightning protection components i e transzorbs or plasma surge arresto...

Страница 8: ...t is in digits 2 Turn the unit on and a reading will appear in the front display window The last digit may change one or two digits while reading Record the value displayed If no reading displays or t...

Страница 9: ...lation To convert digits to deformation the following equation applies Duncorrected R1 R0 G Equation 2 Deformation Calculation Where R1 is the current reading R0 is the initial reading usually obtaine...

Страница 10: ...m Digit mm Polynomial Gage Factors A 0 000000026645441378193 B 0 0094917094213891 C 23 33732890100 Thermal Factor K 0 00853859 mm R0 Original Reading T0 Original Tempera Hereinafter Blank Figure 8 Typ...

Страница 11: ...hese conditions should always be observed and recorded Seemingly minor effects may have a real influence on the behavior of the structure being monitored and may give an early indication of potential...

Страница 12: ...e cable cut or crushed This can be checked with an ohmmeter Nominal resistance between the two transducer leads usually red and black leads is 180 10 Remember to add cable resistance when checking 22...

Страница 13: ...342 2 83 107 9 123 77 66K 36 8006 4 1363 44 331 5 84 105 2 124 72 81K 35 7618 5 1310 45 321 2 85 102 5 125 68 30K 34 7252 6 1260 46 311 3 86 99 9 126 64 09K 33 6905 7 1212 47 301 7 87 97 3 127 60 17K...

Отзывы: