Page: 21/81 User Manual PSU-CTRL-2D, Rev.1-00: Software Utilities
Tab. 3. Command line parameters of the program
COM-HVPSU2D-
Control
- System monitoring.
Parameter Explanation
-v
get the device firmware version
(see function
)
-V
get the device hardware version
(see functions
)
-d
get the device firmware date
(see function
)
-p
get the product identification text
(see function
)
-n, -N
get the product number
(see function
)
-u
get the device uptime
(see functions
)
-U
get the device uptime periodically
-c
get the CPU data
(see function
)
-C
get the CPU data periodically
-h
get the device housekeeping data
(see function
)
-H
get the device housekeeping data periodically
System Monitoring
The command line parameters for system monitoring are listed in
Tab. 3. They are useful in case of a malfunction to collect the data
necessary for describing the issues.
Using the parameter
-u
or
-U
, you can monitor the uptime of the de-
vice:
COM-HVPSU2D-Control 6 -u -t