![CG Emotron VFX Series Скачать руководство пользователя страница 141](http://html1.mh-extra.com/html/cg/emotron-vfx-series/emotron-vfx-series_instruction-manual_2585388141.webp)
CG Drives & Automation,01-5326-01r5
Functional Description
137
Communication information
Within the Skip Speed range High to Low, the speed cannot
be constant in order to avoid mechanical resonance in the
AC drive system.
When Skip Speed Low
≤
Ref Speed
≤
Skip Speed High, then
Output Speed=Skip Speed HI during deceleration and
Output Speed=Skip Speed LO during acceleration. Fig. 106
shows the function of skip speed hi and low.
Between Skip Speed HI and LO, the speed changes with the
set acceleration and deceleration times. Skipspd1 LO sets
the lower value for the 1st skip range.
Communication information
Fig. 106 Skip Speed
Skipspd1 HI sets the higher value for the 1st skip range.
Communication information
The same function as menu [344] for the 2nd skip range.
Communication information
Modbus Instance no/DeviceNet no:
43123
Profibus slot/index
169/27
EtherCAT and CANopen index (hex)
4c33
Profinet IO index
19507
Fieldbus format
Int, 1=1 rpm
Modbus format
Int, 1=1 rpm
NOTE: It is not possible to set the maximum speed
lower than the minimum speed.
Note: Maximum speed [343] has priority over Min
Speed [341], i.e. if [343] is set below [341] then the
drive will run at [343] Max Speed with acceleration
times given by [335] and [336] respectively.
344
SkipSpd 1 Lo
Default:
0 rpm
Range:
0 - 4 x Motor Sync Speed
Modbus Instance no/DeviceNet no:
43124
Profibus slot/index
169/28
EtherCAT and CANopen index (hex)
4c34
Profinet IO index
19508
Fieldbus format
Int, 1=1 rpm
Modbus format
Int, 1=1 rpm
NOTE: The two Skip Speed ranges may be
overlapped.
345
SkipSpd 1 Hi
Default:
0 rpm
Range:
0 – 4 x Sync Speed
Modbus Instance no/DeviceNet no:
43125
Profibus slot/index
169/29
EtherCAT and CANopen index (hex)
4c35
Profinet IO index
19509
Fieldbus format
Int, 1=1 rpm
Modbus format
Int, 1=1 rpm
346
SkipSpd 2 Lo
Default:
0 rpm
Range:
0 – 4 x Motor Sync Speed
Modbus Instance no/DeviceNet no:
43126
Profibus slot/index
169/30
EtherCAT and CANopen index (hex)
4c36
Profinet IO index
19510
Fieldbus format
Int, 1=1 rpm
Modbus format
Int, 1=1 rpm
(NG_06-F17)
n
Skip Speed HI
Skip Speed
LO
Speed Reference
Содержание Emotron VFX Series
Страница 1: ...Emotron VFX 2 0 AC drive Instruction manual English Valid from software version 4 42...
Страница 2: ......
Страница 4: ......
Страница 10: ...6 CG Drives Automation 01 5326 01r5...
Страница 50: ...46 Installation CG Drives Automation 01 5326 01r5...
Страница 62: ...58 Getting Started CG Drives Automation 01 5326 03r5...
Страница 74: ...70 EMC and standards CG Drives Automation 01 5326 01r5...
Страница 90: ...86 Operation via the Control Panel CG Drives Automation 01 5326 01r5...
Страница 218: ...216 CG Drives Automation 01 5326 01r5...
Страница 226: ...224 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r5...
Страница 236: ...234 Options CG Drives Automation 01 5326 01r5...
Страница 256: ...254 Technical Data CG Drives Automation 01 5326 01r5...
Страница 267: ......