5. Basic configuration setting 
 

At the top section of configuration software, user must input the IP 
address and passcode of the GW-1000 which would be connected. The 
default IP address is 192.168.1.120 and passcode is 00000000. 
 

5.1. Status tab 

 

It shows the unit information. Such as firmware version, on board 
voltage. Network information. Weather station data.  
 

5.2. General tab 

 
GW-1000 IP 

Default IP address is 192.168.1.120, netmask 255.255.255.0 
In case, you forget the IP address or the configuration setting corrupted, 
you could choose to go back default setting by open the GW-1000 case 
(Please disconnect the power first). Locate the RESET button. Push and 
hold the button.  Meanwhile connect the power. You will see all the lights 
flash. Then release the button. System does a hard reset.  It will set GW-
1000 to default IP address 192.168.1.120, netmask 255.255.255.0. 
 
 

Router

- the IP address of your router. 

 
Callsign 

– The radio callsign. 

 
SSID -

 This is the SSID for your iGate. Usually it is 10.  

 
Passcode

 – The passcode for APRS IS login. 

 
Filter 

– The APRS server side filter. 

 

APRS server IP  

You could manually setup 3 different APRS server IP address 
 

Polling

 – GW-1000 will try each server if one is not available 

 

Always use Server A

 - Only connect to the 1

st

 server. 

 

 

9

Содержание GW-1000

Страница 1: ...CG Antenna GW 1000 APRS TOTAL SOLUTION v1 2 1 User Manual Last modified 12 Jul 2016 1...

Страница 2: ...Table of Contents 1 Introduction 2 Connectivity 3 Front indicators 4 Software installation 5 Basic configuration setting 6 Bluetooth TNC Optional 7 Reminds 2...

Страница 3: ...1000 could read the APRS data which IS server sent to it and relay to RF 1 3 Weather station report Currently 2 kinds of weather stations are supported 1 Peetbros weather station in Complete record mo...

Страница 4: ...xtension port 2 1 Power supply GW 1000 supports 9 15VDC Current drain 0 8A 2 2 Radio connection port Pin 1 AF OUT GW 1000 audio output to radio input Pin 2 GND ground Pin 3 PTT radio PTT Pin 5 AF IN G...

Страница 5: ...ne by straight connect 4 wires Pin 1 pin 2 pin 3 pin 5 For Yaesu handheld radio there is no PTT wire So user must open the GW 1000 locate the JP3 2 pin jumper which is beside the mini din 6 socket Put...

Страница 6: ...data output of PB data connector 2 4 3 For WX 01 simple weather station connection Connect pin 1 to the 5V of WX 01 Connect pin 2 to the ground of WX 01 Connect pin 6 to the data output of WX 01 Due t...

Страница 7: ...fter connection is established it goes to solid 3 3 APRS receive This indicator is on when GW 1000 is receiving APRS packet 3 4 Decode Encode This indicator is on when GW 1000 is decoding or encoding...

Страница 8: ...nna be driver GW1000v102 zip Download this file and unzip it to your harddisk Step 1 Create a folder on your hard drive E g c gw1000 Step 2 Copy all files into this folder Step 3 Click DOTNET40CLIENT...

Страница 9: ...ld choose to go back default setting by open the GW 1000 case Please disconnect the power first Locate the RESET button Push and hold the button Meanwhile connect the power You will see all the lights...

Страница 10: ...This value is the delay time in milliseconds before sending APRS packet It is necessary for transmit to stabilize the TX frequency also for receiver to synchronize the session TX Skip This value is t...

Страница 11: ...rnet service transmitting interval in seconds 0 means no transmitting RF Report Radio RF transmitting interval in seconds 0 means no transmitting PATH APRS path name GW 1000 supports only WIDE1 WIDE2...

Страница 12: ...terval in seconds 0 means no transmitting RF Report Radio RF transmitting interval in seconds 0 means no transmitting PATH APRS path name GW 1000 supports only WIDE1 WIDE2 and max to 2 hops Latitude L...

Страница 13: ...r on any APRS packet with WIDE2 path Insert Gateway Name Insert gateway name in the new forward APRS packet TX if channel free Transmit the APRS packet when the channel is quiet TX wait This value is...

Страница 14: ...ce it receives the APRS packets from RF IS RF Enable IS to RF GW 1000 will download the APRS data from APRS internet service and transmit out by radio RF Be careful to switch on IS RF it will make you...

Страница 15: ...e the right suitable software and do the next 2 steps to use the GW 1000 as Bluetooth TNC Step 1 Bluetooth pairing your device with GW 1000 On your operating device run the Bluetooth management softwa...

Отзывы: