background image

5

Inspire Electric Fireplace

10009472

Direct (Hard) Wiring Electric Fireplace

 This procedure must be conducted by a qualified elec-

trician, in accordance with National and local codes. In 
the U.S.A., the installation must conform to the National 
Electrical  Code,  ANSI/NFPA  No.  70.  In  Canada,  the 
installation  must  conform  to  the  current  CSA  C22.1 
Canadian Electrical Code.

• 

Make sure the power to the unit is off, and the power 

cord is unplugged from the wall outlet before proceed-
ing with this conversion. Failure to do so may result in 
property damage, personal injury or loss of life.

• 

Make  sure  the  power  to  the  power  cable    has  been 

turned off at the breaker/fuse panel before  proceeding.

NOTE:

 When direct wiring this appliance, it must be 

connected to a 15 Amp dedicated circuit breaker or 

fuse in the electrical panel of the dwelling. The cable 

between the circuit/fuse panel and the fireplace must 

meet all local and national codes, and in no case shall 

the wires be less than 14 gauge.

1.  Make sure the power to the unit has been turned 

off, the master ON/OFF switch located under the 
appliance on the left hand side is turned off, the 
power cord is unplugged from the wall outlet and 
the appliance has cooled down.

2.  Follow Steps 1 through 4 in “Light Bulb 

Replacement” section, Page 9.

3.  Remove two (2) screws per side for the brackets 

and the fireplace screen to be removed and set 
aside.

4.  Remove one (1) screw per side of the bulb housing 

assembly to remove and set aside.

5.  Remove two (2) screws per side for the left side 

cover. This allows the cover to be opened for 
access to where the power cord enters the strain 
relief and the compartment.

6.  Using wire cutters, gently cut the power cord inside 

the  compartment, flush to the strain relief. Also, 
repeat for the power cord outside the compartment.

7.  Back inside the compartment, gently separate the 

three (3) wires of the power cord into separate wires 

WARNING

by gently pulling them apart. DO NOT use a knife, 
as this may expose bare conductors. The hot wire 
is connected to the main power switch and is termi-
nated with a straight terminal connector. The neutral 
wire is connected at the circuit board’s screw clamp 
terminal block. The green ground wire is attached 
to the ground stud. Use a 5/16” (8 mm) socket or 
wrench to remove the brass nut, brass lock washer 
and brass cup washer and set aside. Remove and 
discard the cut power cord ground wire. 

8.  Using a slotted screwdriver, remove the 7/8” (22 

mm) diameter knockout above the old power cord 
strain relief.

9.  Route the power cable from the breaker/fuse panel  

through the 7/8” (22 mm) diameter hole. Secure the 
cable to the compartment using an approved clamp. 
The wires should extend approximately 6” (152 mm)  
into the compartment.

10. Connect the ground wire from the power cable by  

wrapping it around the ground stud of the unit and 
securing it firmly with the brass cup washer, brass 
lock washer and brass nut.

11. Using wire strippers, strip approximately 5/8” (15 

mm) from the ends of the hot and neutral wires. 
Using an approved wire nut, connect the hot lead 
(black) of the power cable to the power cord wire 
that ends at the main power switch. Similarly, using 
another wire nut, connect the neutral wire (white), 
of the power cable to the power cord ending at the 
screw clamp terminal block of the circuit board. It 
is recommended that the wire nuts be taped to the 
wires, using electrical tape, as an extra safety mea-
sure.

12. For extra safety measure, visually check and fix the 

wire routing  appropriately. Refer to the wiring dia-
gram on the unit or in the instruction manual if any 
wires have been dislodged.

13. Turn the power to the unit on at the breaker/fuse 

panel. Place the appliance into operation and check 
to make sure all of the systems are working prop-
erly

Содержание Inspire ICVCEFP01

Страница 1: ...TO INSTALL OR USE THIS FIREPLACE ALWAYS COMPLY WITH ALL WARNINGS AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL TO PREVENT PERSONAL INJURY OR PROPERTY DAMAGE FOR YOUR SAFETY Always use a quali ed te...

Страница 2: ...Hard Wiring Electric Fireplace 5 Fireplace Assembly Unpack the appliance 6 Carton contents 6 Appliance mounting 6 Heater assembly 6 Trim assembly 6 Operating Instructions Heater operation 8 Frequency...

Страница 3: ...the general instructions are followed Also for best effect install the replace out of direct sunlight Clearance to Combustibles Sides including trim assembly 0 0 mm Bottom 9 250 mm Top 3 914 mm SAVE T...

Страница 4: ...nspected if any portion of it has been exposed to water Always utilize a quali ed service technician to inspect the replace and to replace any electrical system components that may have been damaged b...

Страница 5: ...e the compartment 7 Back inside the compartment gently separate the three 3 wires of the power cord into separate wires WARNING by gently pulling them apart DO NOT use a knife as this may expose bare...

Страница 6: ...unt the hanger in place A 3 Phillips screwdriver is recommended Depending on the wall type proper anchors have to be used For your convenience expansion anchors are provided Be sure to check the ancho...

Страница 7: ...agnet location Insert Panel FP1638 Fig 3 Place insert panels on either side of trim 5 Hang the trim to the heater main body s upper trim support at a slight angle and between the trim insert panels Sl...

Страница 8: ...low heat have already been switched on To turn high heat off press the high heat button a second time The re will now be run ning with low heat 5 To place the re in a standby mode at any time press t...

Страница 9: ...s required Always install genuine CFM Corporation replace ment parts which are available from your autho rized dealer Light Bulb Light Bulb Color Film FP1643 Fig 7 Remove color lm and remove light bul...

Страница 10: ...93420 5 Circuit Board B 99610 6 Transmitter B 100830 7 Fan Heater 1097 99660 8 Flame Blower B 99580 9 Power Cord 10009855 10 Landscape Electric Screen B 91130 CFM Corporation reserves the right to ma...

Страница 11: ...lation labor construction transportation or other related costs expenses arising from defective part s repair replacement or otherwise of same will not be covered by this warranty nor shall the Compan...

Страница 12: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: