background image

10009816

9

Service Instructions

WARNING:  Disconnect  power  before 
attempting any maintenance or clean-
ing to reduce the risk of fire, electrical 
shock or personal injury.

• 

Remove Front Cover

Access to heater/fan
1.  Turn off power to the unit.
2.  Let fireplace cool if it has been operating.
3.  Remove the door hat bracket by removing the 

center screw. (Fig. 2) Slowly open doors and 
remove bracket from between the inner and outer 
door frame. (Fig. 3) (Retain bracket)

4.  To remove the doors, locate and remove the two 

(2) screws holding the door at the top. (Fig. 3) 
Hold the door at all times with one hand to prevent 
the door from falling when you undo the hinge 
screws.

5.  Locate the screws that hold the front cover in 

place. There are six (6) screws, three (3) located 
on the front of the unit (Fig. 4) (center screw was 
removed in Step 3), and three (3) located under-
neath the top shelf of the unit.  (Fig. 5)

6.  Remove screws using appropri-

ate screwdriver.

7.  Pull out the front cover. Holding 

both sides of the cover, pull gen-
tly towards you and down.

8.  You now have access to the 

heater/fan unit, for cleaning and/
or maintenance.

������
�������������������
����

Remove Screws

FP1734

Figure 4

�������
�����������������������
����

Remove Screws

Figure 5

������
������������
����

Figure 6

FP1736

Figure 2

������
�����������
����

Remove 

Screw

FP1873

������
�����������
����

Remove Screws

Figure 3

FP1874

Remove Bracket

9.  To reinstall the front cover, please follow reverse pro-

cedure, paying attention not to damage any wiring in 
the process.

NOTE:

 The door hat bracket 

MUST BE

 replaced when 

the fireplace is installed in an RV. The door hat bracket 
may be discarded for all other installations, however the 
screw retaining the hat bracket 

MUST BE

 installed for all 

installations.

Содержание EF22

Страница 1: ... THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY Service must be performed by a qualified service agency DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE INSTALLER Leave this manual with the appliance CONSUMER Retain t...

Страница 2: ...EA ARRÊT Appelez nous sans frais États Unis 1 800 668 5323 Canada 1 800 668 5323 Du lundi au vendredi de 9 h 00 à 17 h 00 HNE Call Toll Free Canada 1 800 668 5323 USA 1 800 668 5323 Monday to Friday 9 00 A M to 5 00 P M E S T POUR NOUS AIDER À VOUS AIDER Veuillez remplir les données suivantes Conservez ce Manuel du propriétaire et preuve d achat pour consultation ultérieure ALTO Llame sin costo Es...

Страница 3: ...ble of Contents Safety Information 4 Installation Instructions Fireplace Dimensions 5 Electrical Specifications 5 Locating Your Fireplace 6 Clearance to Combustibles 6 Cabinet Installations 6 Electrical Connection 7 Grounding Instructions 7 Direct Hard Wiring Electric Fireplace 8 Service Instructions Remove Front Cover 9 Glass Information 10 Replacing the Light Bulbs 10 Maintenance of Motors 11 Cle...

Страница 4: ...ug from outlet 12 Connect to properly grounded outlets only 13 This appliance when installed must be electrically grounded in accordance with local codes with the current CSA C22 1 Canadian Electrical codes or for USA installations follow local codes and the National Electric Code ANSI NFPA No 70 14 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may caus...

Страница 5: ... 819 mm 35 895 mm H 15 381 mm 19 495 mm 22 578 mm 26 667 mm J 33 860 mm 31 787 mm 36 916 mm 38 971 mm K 46 1179 mm 43 1114 mm 51 1295 mm 54 1373 mm L 23 590 mm 21 557 mm 25 648 mm 27 687 mm F C E A B D G H 1 25 mm J K L J EF22 26 33 36 Fireplace Dimensions NOTE Add 1 4 7 mm to Ref C and D dimensions for wall cabinet opening clearance Units EFJU4D0 EF0U4F0 EF0U4I0 EF0U4J0 EFJUF50 Electrical Specific...

Страница 6: ...ed through the fireplace sides for 8 x 3 4 long black oxide wood screws or similar The mounting holes can be located on left and right sides approximately 2 51 mm from the top and 5 127 mm from the bottom of the glass door area The mounting hole location distance from the front of the unit must not interfere with the glass door and the refractory brick pattern when rein stalled If necessary modify...

Страница 7: ...d and must not be longer than 50 ft 15 2 m Do not coil or cover the extension cord Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire electrical shock and injury to persons Do not use this fireplace if any part of it has been under water Immediately call a qualified service technician to inspect the fireplace and replace any p...

Страница 8: ...t and remove the power cord Dispose of the power cord 8 Using a slotted screwdriver remove the 7 8 22 mm diameter knockout from the right hand side of the cabinet above where the strain relief was located 9 Route the electrical cable from the breaker fuse panel through the 7 8 22mm diameter hole and secure to the cabinet using an approved clamp The power wires should extend approximately 6 152mm i...

Страница 9: ...in place There are six 6 screws three 3 located on the front of the unit Fig 4 center screw was removed in Step 3 and three 3 located under neath the top shelf of the unit Fig 5 6 Remove screws using appropri ate screwdriver 7 Pull out the front cover Holding both sides of the cover pull gen tly towards you and down 8 You now have access to the heater fan unit for cleaning and or maintenance Remov...

Страница 10: ... may result in a fire causing property damage personal injury or loss of life 1 Turn off power to the unit 2 Let fireplace cool if it has been operating 3 Open the front doors 4 Remove the door hat bracket by removing the center screw Fig 2 Slowly open doors and remove bracket from between the inner and outer door frame Fig 3 Retain bracket 5 To remove the doors locate and remove the two 2 screws ...

Страница 11: ...rvicing operation The motors used on the fan heater and flame blower are pre lubricated for extended bearing life and require no further lubrication However periodic cleaning vacuum ing of the appliance around the air intake and exhaust as well as the fan heater is recommended For heavy or continuous use periodic cleaning must be done more frequently If the heater blows alternating cold and warm a...

Страница 12: ...pairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes NOTE EF22 26 use 2 instead of 3 light bulbs for flame and ember bed WARNING Disconnect Power Before Servicing 1 Fan Heater 2 Circuit Board 3 Motor DC 4 Light Socket w Wiring Assy 5 Light Bulb 6 Wire Clip 7 Bushing Snap 8 Strain Relief 9 Power Cord 16 3 Any electrical re wiring...

Страница 13: ...e fire along with the heat output of a heater As a visual effect only flame effect is on the heater is off We recommend this mode for warm weather application when you want the ambiance of a fire with out any heat output As a heater only heater is on while the flame effect is off This mode allows you to use your fireplace as an electric heater without any flame effect Refer to Figures 11 12 for lo...

Страница 14: ... heater between the lowest lowest light bar and highest highest light bar To determine the room temperature depress button 5 or 6 to decrease or increase until the heater goes off or comes on The heater is designed to safely deliver the maximum amount of heat when it is turned on To increase the room temperature depress button 6 to increase room temperature setting When the set temperature is reac...

Страница 15: ... Refractory Right side 10010090 10010091 10010093 10010095 5 Refractory Left Side 10010090 10010091 10010092 10010094 6 DC Motor 10009621 10009621 10009621 10009621 7 Flame Generator Assembly 10003566 10003566 10003350 10003350 8 Glass Operable Door Assembly Left 10009269 10009271 10009273 9 Glass Operable Door Assembly Right 10009270 10009272 10009274 10 Socket w Wire Assembly 10006453 10006453 1...

Страница 16: ...or construction transportation or other related costs expenses arising from defective part s repair replacement or otherwise of same will not be covered by this warranty nor shall the Company assume responsibility for same Further the Company will not be responsible for any incidental indirect or consequential damages except as provided by law 7 All other warranties expressed or implied with respe...

Отзывы: