C-net 2000 MULTI
28
1.4
Switch the power back on and wait for the C-net 2000
to completely power up, and then switch the power off.
1.5
Remove the jumper from LK2, and replace it in the
original position on the calibration link.
1.6
Replace the cover, and switch the system power back on.
STEP 2
2.1
Return the C-net 2000 to the compass calibration
page and resume the calibration routine:
2.2
Press Cal Now button. (Compass status will change
to INT).
2.3
As soon as the vessel starts to move, in a clockwise
direction, the status will change to RUN.
2.4
When the compass has completed its deviation turns,
the compass status will read CORR.
Compass calibration is now complete.
This next setting allows the compass reading to be aligned
to a known, correct heading. Use the keys to adjust the
heading reading to the correct one.
DAMPING
This allows readings to be damped if they change too fast
so that they change slower and can be read.
The range is 0 (undamped) to 9 (maximum damping).
LANGUAGES
The language used on all C-net 2000 units in the system is
changed here.