QMIX λ
Hardware Manual
ORIGINAL MANUAL 3.00 – FEBRUARY 2016
Страница 1: ...QMIX Hardware Manual ORIGINAL MANUAL 3 00 FEBRUARY 2016...
Страница 2: ...2 Qmix Hardware Manual CETONI GmbH Wiesenring 6 07554 Korbussen Germany T 49 0 36602 338 0 F 49 0 36602 338 11 E info cetoni de www cetoni de...
Страница 3: ...rm the purchaser of any alterations new developments or improvements to the software or make these available to him No legally binding assurance of certain features is given CETONI GmbH is not liable...
Страница 4: ...4 Qmix Hardware Manual...
Страница 5: ...al data 8 3 3 Electrical data 8 3 4 Interfaces 8 3 5 Wetted parts 9 4 Use 10 4 1 General description of the device 10 4 2 Intended use 10 4 3 Reasonably foreseeable faulty application 10 4 4 Safety ad...
Страница 6: ...inor changes 1 10 12 09 2013 Added Qmix BaseXT and TC power consumption Q 1 11 21 08 2014 Adaptation of the maximum heating temperatue of the Reaction module Q heating column and the High temperature...
Страница 7: ...rdware Manual 7 2 Scope of supply The following items should be included in the scope of supply QMIX MODULE Spectrometer as ordered Light source as ordered OCEANVIEW SPECTROSCOPY APPLICATION MANUAL HA...
Страница 8: ...ondensing STORAGE HUMIDITY 20 90 non condensing 3 2 General data DIMENSIONS L X W X H 310 x 75 x 90 100 mm WEIGHT 0 9 kg 1 1 kg WAVELENGTH RANGE Depending on the configuration MAXIMUM PRESSURE 10 bar...
Страница 9: ...Qmix Hardware Manual 9 3 5 Wetted parts WINDOW fused silica SiO2 LIGHT SOURCE PPS polyphenylene sulfide MEASUREMENT SECTION PTFE tubing SEALS FPM...
Страница 10: ...e omitted CAUTION The unit must not be used as a medical device or for medical purposes 4 4 Safety advice For the safe operation of the Qmix modules it is necessary to observe the safety measures from...
Страница 11: ...original packaging Use the original packaging for transportation or shipping of the module Concerning the storage conditions please observe the data from chapter Technical data CAUTION Risk of damagi...
Страница 12: ...ge of 350 to 1100nm It provides an integrated LED light source which can be adapted to the required wavelength range An adapter with SMA 905 connector is also available The larger module can be adapte...
Страница 13: ...Note the safety information concerning wavelength and optical power When using an external light source read the associated manual of the manufacturer and follow the safety instructions therein 6 1 D...
Страница 14: ...window has to be placed with this side first Attach the connection piece to the holder on the module with two M2 5x8 screws using a 2 mm Allen key It may be helpful to hold the module upright lest the...
Страница 15: ...sides The PTFE tubing can be used optionally Finally the second connection piece is mounted When the shortest intermediate piece is used the final connection piece is screw mounted directly on the exi...
Страница 16: ...t is your decision which of the ports you would like to be in or outlet 6 3 Light source The small module provides an integrated LED light source The brightness of the LED can be adjusted to your need...
Страница 17: ...wo marked screws with a phillips screwdriver and then simply exchange the LED attachment Please do not remove the smaller screw in the centre If you want to mount the SMA 905 adapter instead of the LE...
Страница 18: ...18 Qmix Hardware Manual Mounting plate SMA 905 adapter Window and O Ring...
Страница 19: ...mbH to coordinate further actions The device may only be opened by CETONI GmbH or thereby authorized service staff Otherwise the warranty and guarantee claims are void Software related troubles are de...