APPEARANCE
The device is designed for single-
phase installation and must be installed
in accordance with standards valid in a
particular country. The device should
be connected according to the details included in
this operating manual. Installation, connection and
FRQWUROVKRXOGEHFDUULHGRXWE\DTXDOL¿HGHOHFWUL
-
cian staff, who act in accordance with the service
manual and the device functions.
In case of casing dismantling an electric shock
may occur, and the guarantee is lost then. Before
installation make sure the connection cables are
not under voltage. The cruciform head screwdriver
3,5 mm should be used to instal the device. Im-
proper transport, storage, and use of the device
LQÀXHQFHLWVZURQJIXQFWLRQLQJ,WLVQRWDGYLVDEOH
to instal the device in the following cases: if any
device part is missing or the device is damaged or
deformed. In case of improper functioning of the
device contact the producer.
The symbol means selective collecting
of electrical and electronic equipment.
It is forbidden to put the used equip-
ment together with other waste.
CAUTION!
FEATURES
TECHNICAL DATA
DESCRIPTION
Ɣ /&'GLVSOD\VKRZVFXUUHQWURRPWHPSHUDWXUH
Ɣ
economical and comfort mode operation;;
Ɣ
optional temperature display: Celsius or
Fahrenheit (temperature) scales;;
Ɣ
temperature control by means of (internal)
EXLOWLQVHQVRURUH[WHUQDOÀRRUVHQVRU
Ɣ
easy, intuitive service.
RTS-01 temperature controller is not a pro-
JUDPPDEOHUHJXODWRUDQGLVXVHGLQÀRRUKHDW
-
ing. The device cooperates with electric and
ZDWHUÀRRUKHDWLQJV\VWHPV576FDQFRQ
-
trol temperature by means of (internal) built-in
VHQVRURUH[WHUQDOÀRRUVHQVRU
The regulator should be installed:
Ɣ LQDKHDWLQJURRPPRXQWLQJÀDWVXUIDFH
or installation cable box Ø60 mm);; 120
FPKLJKIURPWKHKHDWLQJ]RQH
Ɣ LQDSODFHQRWH[SRVHGWRGLUHFWVXQOLJKW
Ɣ LQ D SODFH QRW H[SRVHG WR VWURQJ ZLQG
blows.
7KH WHPSHUDWXUH UDQJH RI WKH PRXQWLQJ
SODFH·R&
RTS-01
Input (supply) terminals: L (5), N (6)
Input rated voltage: 100 ÷ 240 V~
Nominal frequency: 50 / 60 Hz
Nominal power consumption:
:67$1'%<
Battery support: none
NTC senor terminals: RT+, RT-
Temperature senosor: NTC 100 k for 25 ºC
Room temperature adjustment range: +5 ÷ +30 °C
Floor temperature control range: +5 ÷ +40 °C
Accuracy of temperature measurement: ±1 °C
Relay parameters: 5 A / 230 V~
Number of terminal clamps: 6
Section of connecting cables: 0,5 ÷ 1,5 mm
2
Ambient temperature range: -5 ÷ +50
o
C
Casing mounting: surface
Casing protection degree: IP21
Protection level: II
Overvoltage category: II
'LPHQVLRQV
86 x 86 x 38 mm
Weight: 0,114 kg
Reference standard: PN-EN 60730-1:2002, PN-EN 60730-2-9:2006,
PN-EN 61000-3-2, PN-EN 60730-3-3,
PN-EN 55022, PN-EN 61000-4-3,
PN-EN 55014-1:2007+A1:2010,
PN-EN 61000-4-4, PN-EN 61000-4-5,
PN-EN 61000-4-11, PN-EN 61000-4-2,
PN-CISPR 16-2:1999,
PN-CISPR 16-1:1997+A1:2000
Main switch
Base mounting screw
/&'GLVSOD\
Adjustment knob
Temperature sensor terminals
Modes operation switch
Relay output terminals
Input (supply) terminals
heating mat