background image

1.2 Target groups of this manual

If a section of this manual is intended for a particular target group, this is stated at the start of the section. Sections that do not

specify a particular group are relevant for all target groups.

Target group

Skills

CEStronics partners

are trained experts in locking and security technology that have also worked with CES for many years and have a special level

of product knowledge.

Particular characteristics of the target group:

l

Detailed knowledge of CES products

l

Participate regularly in product training

Locking and

security technology

specialists

have many years of professional experience and/or relevant training in locking and security technology. For some tasks it may

be necessary for specialists to have received training on the product beforehand.

Particular characteristics of the target group:

l

Knowledge of specialist terminology from the field of locks and handles

l

Knowledge of specific risks when mounting electronic cylinders and handle sets, for example

l

Experience of working with tools (relevant to lock systems)

l

Knowledge of relevant standards and regulations, e.g. for fire safety or emergency and escape routes

l

Basic understanding of electronic locking systems

Electricians

have many years of professional experience and/or relevant training in electronics. For some tasks it may be necessary for

specialists to have received training on the product beforehand.

Particular characteristics of the target group:

l

Knowledge of specialist electrical terminology and its symbols

l

Knowledge of the risks associated with handling sensitive electronic components

Personnel with

product training

have received training on the product by CES or a CEStronics partner. Here the personnel are given detailed and specific

information to prepare them for the required task.

Particular characteristics of the target group:

l

Knowledge of CEStronics products and experience in handling them (assembly, operation, etc.)

IT/administration

specialists

have many years of professional experience in the fields of IT structures, administration and networks.

Particular characteristics of the target group:

l

Knowledge of specialist IT terminology

l

Knowledge of the structure and maintenance of networks, particularly knowledge of the network that they maintain

System operators

have experience in the management of master key systems. This can be either a number of systems or a detailed knowledge

of a single master key system.

Particular characteristics of the target group:

l

Knowledge of the specialist terminology related to master key systems

l

Skilled in the use of PCs and software

End users

do not require specific skills.

www.ces.eu

Subject

to

change

without

notice.

BRO

2327

VA1

Содержание AccessOne PHG Voxio Display

Страница 1: ...AccessOne Online reader Reader PHG Voxio Display Assembly and operating manual English Version VA1 BRO 2327 www ces eu Subject to change without notice BRO 2327VA1...

Страница 2: ...and designations of parts 9 4 Terminal wiring specification 10 5 Assembly 11 5 1 Assembling the reader 11 5 2 Removing the reader 17 6 Setting up the reader updater in AccessOne 18 7 Operation 22 7 1...

Страница 3: ...document may be copied or transmitted for any purposes whatsoever without the express written consent of C Ed Schulte GmbH Zylinderschlossfabrik 2021 C Ed Schulte GmbH Zylinderschlossfabrik Velbert G...

Страница 4: ...ofessional experience and or relevant training in electronics For some tasks it may be necessary for specialists to have received training on the product beforehand Particular characteristics of the t...

Страница 5: ...ation terminal in an AccessOne access control system The product is intended solely for and may only be used for this purpose Any other use is deemed to be improper use and could result in property da...

Страница 6: ...an explosion and individuals could be injured Do not use the device in potentially explosive areas 2 3 3 Danger of material damage Hard shocks Hard shocks can damage mechanical and electronic componen...

Страница 7: ...Lassen Sie das Ger t halbj hrlich ausschlie lich durch CES oder Fachpartner warten und auf fehlerfreie Funktion pr fen Always have repairs performed by qualified personnel Use only accessories and sp...

Страница 8: ...n access terminal the reader offers the option of operation with or without ID medium In this case the ID number is entered using the capacitive touch keypad Allocation of an additional PIN code enabl...

Страница 9: ...delivery and designations of parts Flush mounted variant Surface mounted variant 1 Reader 2 Fixing screws 3 Wall mount 4 Connection terminal 5 Locking bar www ces eu Subject to change without notice...

Страница 10: ...aining l IT administration specialists Risk of damage Perform all work on and in the device with the power supply disconnected Terminal number Designation 1 RS485 data A 2 RS485 data B 3 Output 1 4 Ou...

Страница 11: ...sk of damage Perform all work on and in the device with the power supply disconnected 5 1 Assembling the reader 5 1 1 Assembling the flush mounted variant 1 Slide the wall mount off the reader 2 Screw...

Страница 12: ...m 9 Guide the cable strands through the cover cap and wire them to the terminal in accordance with the connection diagram Risk of damage Perform all work on and in the device with the power supply dis...

Страница 13: ...on the wall mount 14 Press onto the positioned reader and slide it downwards until it audibly clicks into place 15 Slide the locking bar into position until it audibly clicks into place The reader is...

Страница 14: ...surface mounted frame onto the wall 3 Secure the tear off tab for tamper detection with a screw 4 Remove the cover cap from the reader 5 Remove the connection terminal 6 Set DIP switch 5 to ON 7 Use D...

Страница 15: ...l work on and in the device with the power supply disconnected 10 Attach the connection terminal 11 Replace the cover cap Risk of equipment damage by entry of moisture Careful sealing is required to s...

Страница 16: ...ed reader and slide it downwards until it audibly clicks into place 15 Slide the locking bar into position until it audibly clicks into place The reader is now installed www ces eu Subject to change w...

Страница 17: ...s insert a screwdriver into the release openings and press gently until the locking mechanism disengages 2 Pull the locking bar out towards you 3 Slide the reader upwards 4 Lift the reader carefully a...

Страница 18: ...is normally performed using an ID medium In certain areas an additional PIN prompt offers increased security Identification can however also take place without an ID medium whereby the user manually e...

Страница 19: ...ations tab Assigned Readers area and enable the Time Registration function If the user does not have time registration rights no time registration entry is generated even if Coming appears in the read...

Страница 20: ...o the value 256 from step 1 256 7 263 EXAMPLE 2 Holding up an authorised ID medium without activating the keypad should generate a Going message when the door is opened It should also be possible to e...

Страница 21: ...n The content of the Name field is displayed in the reader updater display if requested A maximum of 10 characters are displayed By entering the character string the position at which the name ends on...

Страница 22: ...code 7 1 2 Access with ID number plus PIN code Prerequisite l PIN code required parameter is enabled select Device data dialogue Parameters tab PIN code required parameter l PIN is created in master d...

Страница 23: ...led select Device data dialogue Parameters tab parameter Gen erate time registration message 7 3 Information function Prerequisite l The Info terminal with display door model must be selected select D...

Страница 24: ...ehlerfreie Funktion pr fen 8 2 Care for your devices You can clean the external accessible parts of your devices housing labelling etc with a soft slightly damp cloth Do not use oils or lubricants to...

Страница 25: ...hold waste Electronic equipment contains a wide variety of substances and materials If waste electrical and electronic equipment WEEE is not disposed of correctly environmental and health risks may ar...

Страница 26: ...C Ed Schulte GmbH Zylinderschlossfabrik Friedrichstra e 243 D 42551 Velbert 49 2051 204 0 49 2051 204 229 info ces eu www ces eu...

Отзывы: