Cerwin-Vega CV-1800 Скачать руководство пользователя страница 2

IMPORTANT SAFETY INSTRUCTIONS

1. Read Instructions – All the safety and operating instructions should be read before

this product is operated.

2. Retain Instructions – The safety and operating instructions should be retained for

future reference.

3. Heed Warnings – All warnings on the appliance and in the operating instructions

should be adhered to.

4. Follow Instructions – All operating and use instructions should be followed.

5. Do not use this amplifier near water. The amplifier should not be used near water

or moisture or dripping or splashing — for example, in a wet basement, in the
rain, or near a swimming pool. Objects that contain liquids, such as vases, shall
not be placed on the ampllifier.

6. Clean only with dry cloth.

7. Do not block any ventilation openings. Pleaase install in a well ventilated

environment.

8. Do not install near any heat sources such as radiators, heat registers, stoves, or

other apparatus (including amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or gounding plug. A polorized

plug has two lnades with one wider than the other. A grounding plug has two
blades and third prong. The wide blasde or the third prong is provided for safety.
If the provided plug does not fit into your outllet, consult an electician for
replacement of the obsolete outlet.

10. WARNING: The mains plug or amplifier power inlet is used as a disconnet

device, the disconnect device shall remain readily operable. Protect the power
cord from being walkied on or pinched particularly at theplugs, conenience 
receptacles, and at the point where  they exit from the amplifier.

11. Use only attachments/accessories specified by the manufacturer.

12. Use this amplifier only withcarts and rack equipment rated

for this type of equipment. When a cart or rack is used use
caution when moving to avoid injury from a tip-over.

13. Unplug the amplifier during lightening storms or when

unused for longperiods of time.

14. Refer all servicing to qualified personnel. Servicing is required when the

amplifier has been damaged in any way, such as the power cord is damaged,
objects have fallen into the amplifier, the amplifier has been exposed to rain or
moisture, has been dropped or does not operate normally.

16.This amplifier should only be operated from the type of power source indicated

on the rating label. If you are not sure of the type of power coming from your wall
socket, consult your product dealer or local power company.

!7. WARNING: to prevent hazardous electrical shcok do not touch the conductive

parts of the out put terminals. The external wiring connected to these terminals
requires installation by a qualified technician.

18. This product is in compliance with EU WEEEE regulations.

Disposal of end of life of product shoud not be treated as
municipal waste. Please refer to your local regulations for
instructions on proper disposal of this product.

CAUTION: To reduce the risk of electric shock, do not remove any
cover. No user-serviceable parts inside. Refer servicing to 
qualified service personnel only.

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the user
to the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of
sufficient magnitude to constitute a risk of electric shock.

The exclamation point within the equilateral triangle is intended to alert the user to the presence of
important operation and maintenance (servicing) instructions in the literature accompanying this 
appliance.

CAUTION:

To prevent electric shock, do not use this polarized plug with an extension cord, receptacle or other

outlet unless the blades can be fully inserted to prevent blade exposure.

"Protective earthing terminal.The amplifier should be connected to a mains socket outlet with a
protective grounding connection terminal. The amplifier should be connected to a mains socket
outlet with a proper gounding connection for safe operation.

Caution Hot Surface! Heat danger. Please don’t touch the area because a high temperature 
danger may exist. Use caution when touching surfaces makred with this logo as they may become
hot during extend use.

This lightening flash is intended to alert the

user to the presense of non-insulated “dangerous

voltage” on the output terminals that may be of sufficent magnitude to constitute a risk of electric
shock. The external wiring connected to the terminals requires installation by an instructed person or
the used of ready -made leads or cords. of

Содержание CV-1800

Страница 1: ...CV 900 CV 1800 CV 2800 HEAVY DUTY PROFESSIONAL AMPLIFIERS USER MANUAL...

Страница 2: ...xposed to rain or moisture has been dropped or does not operate normally 16 This amplifier should only be operated from the type of power source indicated on the rating label If you are not sure of th...

Страница 3: ...ing to the description on the following pages FEATURES Cerwin vega amplifiers deliver the following power ratings CV 900 2 x 210 Watts at 8 ohm 2 x 320 Watts at 4 ohm and 2 x 420 Watts at 2 ohm CV 180...

Страница 4: ...use If the clip indicator is illuminated then simply lower the channel gain or input signal until the indicator does not light 6 Active Indicators These blue LED s indicate that AC power is connected...

Страница 5: ...p sub audio inputs 5 Limiter switch When the input signal connected to your amplifier is too high you end up with a distorted output signal To prevent this both chan nels feature a clip limiter that c...

Страница 6: ...nt the limiter circuitry will be activated This is indicated by illumination of the Clip LED The channel gain is automatically reduced protecting the speakers from high power Uncontrolled feedback osc...

Страница 7: ...ral amplifier One channel pushes and the other channel pulls equally doubling the power over that of either channel alone Therefore the voltage is doubled the peak power is quadrupled and program powe...

Страница 8: ...ged Mono Mode B B SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 2 SPK to PIN 2 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1 SPK to PIN 1...

Страница 9: ...9 WIRING These are several ways to interface to the amplifier to support a variety of applications Unbalanced 1 4 Connector Balanced TRS 1 4 Connector XLR Balanced Wiring Guide Speakon Connector...

Страница 10: ...10 SPECIFICATIONS...

Страница 11: ...amplifiers are designed to work with many different speakers on the market They have been paired with the following Cerwin Vega speakers The following compatibility matrix can be used as a reference...

Страница 12: ...venient monitoring of the amplifier s status and the right connectors for integration into most any environment The CV Series Amps are right for the job P R O F E S S I O N A L A U D I O FEATURES BENE...

Отзывы: