Base Unit
2019 Cervis, Inc.
23
C5: BU-xH6R/XX-218 Remote Communication
Caution
To prevent inadvertent machine movement, be sure to
remove power from the Base Unit before attempting to
Associate or Dissociate.
To Associate (see Figure 13)
Associate mode is used to establish the communications link between the 18-button handheld
remote and base unit on a 1-to-1 basis.
To Associate:
There must be a clear line of sight between the handheld and the base unit
The handheld must be near the base unit
—within six feet
Both units must be OFF (powered down)
Turn off the 18-button handheld by pressing its OFF button when the unit is ON, or by allowing
the unit to time-out. Off is indicated when none of the LEDs are active when any function button
is pressed. Safely power down the SmaRT base unit by disconnecting the power source from
the unit.
Figure 13. XX-218 Associate Mode
Note: Observe LED states while performing the following procedure.
1. Remove power from the base unit (disconnect the P1 and P2 cables or turn the
source power OFF), and turn off the handheld.
2. Stand near the base unit with the handheld in a clear, unobstructed line-of-sight.
3. Press and hold
button 2
, then press and hold
button 1
. Hold both buttons
simultaneously.
4. Wait until the amber LED2 goes out.
Release the two buttons being held.
5. Press and release button B16. The GREEN LED1 and the RED LED3 turn
ON
.
6. Power up the base unit.
1