Base Unit
2019 Cervis, Inc.
21
Figure 11. MCB Switch Actuation for Associate and Dissociate
To Dissociate (see Figure 11)
The MCB remote must be OFF and the base unit must have power removed before the Dissociation
process can be started.
Note: The Machine Stop button must be in the UP position before activating and using the
console remote.
1. Stand near the base unit with the remote
OFF
and
power removed
from the
base unit (disconnect the P1 and P2 cables or turn the source power OFF).
2. Release the
STOP
button on the MCB handheld by pulling it up.
3. Push and hold switch
SW1 DOWN
; then press the
Power ON
button. All four
LEDs light solid.
4. Observe the LEDs. When TX begins to blink, power up the base unit while
continuing to hold switch SW1 and the Power button. When all four LEDs light
solid, release SW1 and the pushbutton.
Note: Be aware that all remote associations to the base unit are now broken.
Power ON
SW1
Pull
UP
SW1
Pull
UP
ASSOCIATE
DISSOCIATE