13
Troubleshooting
Before preforming any work outlined in this section please read through it thoroughly.
CTMW
recommends that only Certified Mechanics and Certified Electricians preform the steps
outlined below. Failure to do so can result in serious bodily injury or even death
.
If after
exhausting the steps outlined below your machine is still not functioning properly please call
our technical department at
1-800-237-7841
for further assistance.
1.
Machine will not Start/No Ready Light:
a.
Check power cords for proper connection.
b.
Make sure the Disconnect Switch is i
n the “On” position.
c.
Make sure Emergency Stop Button is pulled out.
d.
Check if Selector Switch is turned to the controls you are using, either Corded
Remote Control or Wireless Remote Control.
e.
Check Remote Control Cord for broken connections.
f.
Check that the circuit breakers are not tripped on the control panel.
g.
Check that the Hopper Interlock Switch is depressed and in working condition.
h.
Check batteries in Radio Remote (if applicable).
i.
Check that the antenna on the radio receiver is connected and clear of signal
blockage (if applicable).
j.
Check that there is adequate shore power or power from the generator.
2.
Blowers not working:
a.
Check electrical connections to make sure nothing has been disconnected.
b.
With power on and all safety requirements in place, look at the back of the
blowers to see if they are spinning, if not replace.
3.
Insufficient air:
a.
Check to see if blowers are operating properly
b.
Check to see if material hose is clogged or restricted
c.
Check air stream hose connections for blockage