Cerlic MultiFix Скачать руководство пользователя страница 1

   

2015-­‐12-­‐01   
   

   

C85C5EN16   

   

MultiFix   

   
   

   

   

   

Manual   

   

   

   
   

   
   
   

   MultiFix   

Central   unit   

   

   

   

   

Содержание MultiFix

Страница 1: ...2015 12 01 C85C5EN16 MultiFix Manual MultiFix Central unit...

Страница 2: ...20 MA OUTPUTS 10 ACTIVE OR PASSIVE OUTPUT 10 RELAY OUTPUTS 11 MAINTENANCE 11 TROUBLESHOOTING 11 CONTACT INFORMATION 12 WARRANTY 12 TECHNICAL SPECIFICATION MULTIFIX 12 APPENDIX 1 OXYDUO DISSOLVED OXYG...

Страница 3: ...3 MultiFix TROUBLESHOOTING 17 CALIBRATION 18 Calibration with sludge 18 Lab test 18 Zeroing 18 SPECIFICATION SOLIDO 19...

Страница 4: ...in recovering electrical and electronic waste If this waste is not recovered in accordance with the regulations EU Directive 2002 96 EC both the environment and human health may be endangered Descrip...

Страница 5: ...a sensor is connected the MultiFix unit asks what position the sensor should be installed in If a sensor has already been installed in this position MultiFix asks whether the previous sensor should be...

Страница 6: ...d under Preferences Light time Description of display In the standard version at start up the display looks like the Figure below It shows the type of sensor the measuring unit and the temperature on...

Страница 7: ...shold 1 and Threshold 2 The relays are independent of each other and can be used as Min and Max alarms for example The settings depend on the sensor that is connected The screenshot below shows an exa...

Страница 8: ...p up in the menu using or down using until your desired language is shown and confirm with Then back out of the menu with until it closes Time and date To set the time and date Press to open the menu...

Страница 9: ...tration The following units are available to display the measurements g l mg l and ppm Press to open the menu Step down with and select Setup using Step down in the menu with and select Conc unit Conf...

Страница 10: ...the measurement or the temperature Under Scaling 4 mA and Scaling 20 mA you can set the Min and Max values for the measuring range in correspondence to the output signal Outputs 2 4 are configured in...

Страница 11: ...ong life The sensor and the cable clamps are of the MatchClamp type to guarantee no leaky contacts or distorted cables Troubleshooting Screen on the central unit is blank Check the fuses in and to the...

Страница 12: ...y and will repair the instrument if it is found that the problem is traceable to our production or equipment The warranty applies within a specified period Technical specification MultiFix Number of s...

Страница 13: ...13 MultiFix Appendix 1 Oxyduo Dissolved Oxygen Sensor Oxyduo Dissolved Oxygen Sensor for liquids...

Страница 14: ...ss steel SS 2343 SS316 The sensor cable is specially made in PUR with a strong shield and extra strands for long life The sensor and the cable clamps are of the MatchClamp type to guarantee a watertig...

Страница 15: ...best result in high humidity air and wait until the temperature reading is stable Confirm with When air calibration is complete back out of the menu with all the way to the main menu and the measurem...

Страница 16: ...16 MultiFix Appendix 2 Solido Suspended Solids Sensor Solido Suspended Solids Sensor...

Страница 17: ...a deposit has accumulated on the lenses in the measuring gap To check whether cleaning is needed the sensor should be dipped in clean de aerated water The measurement on the display should not differ...

Страница 18: ...ntration Press to open the menu and step down using Then select Calibration with Step down with and select Lab test Confirm with Change the old value to the new one obtained from the lab analysis usin...

Страница 19: ...ge type Accuracy sludge 1 FS full scale Repeatability 2 of measured value Type of measurement Continuous Measuring units g l mg l ppm Max depth 19m Temperature range sample 0 50 C Sensor body Stainles...

Отзывы: