background image

V1.5 

 

 

Product Application 

 

 

 

 

 

 

 

 

 
 
 
Installation 

 

Distance between installations

 

The cabling distance between the surge protector (POE-OSP) and the 
protected device should be less than 1 meter. 
The closer the POE-ISP is installed to the protection device,

 

the more 

effective it is for the protection device. 

 

DEVICE

Port

 

This port support

 

transmit up to 74 Watt four pair of PoE power is used 

for connecting the unit to the outdoor Ethernet device it will be protecting 
(e.g. PoE access point or PoE IP camera).

 

 

LINE IN

Port

 

This port support receive up to 74 Watt four pair of PoE power from that 
device is used for connecting the unit to the outside network. 

 
Units Combination 

This device can be can be combined with multiple units for easy to 

bundles organize the Ethernet cables.

 

 

 

 

 

 

 

 

 

 

Connect a ground wire

   

The unit must be grounded,

 before connecting the grounding wire size, 

We recommend using a 12~18 Gauge (AWG) (copper wire diameter) size 
for the grounding cable. 
 

Ground wiring length 7.5 meters

 

Please use 18 Gauge (AWG) size

 

Ground wiring length 15 meters

 

Please use 16 Gauge (AWG) size

 

Ground wiring length 30 meters

 

Please use 14 Gauge (AWG) size

 

Ground wiring length 60 meters

 

Please use 12 Gauge (AWG) size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please refer to the following how to ground the POE-ISP. 

First remove the grounding screw on the side of the unit. Place the 

ground wire of the connected O-type terminal on the ground screw hole.   

Insert and tighten the grounding screw firmly to secure the grounding 

wire and the ring to the device. Connect the other end of the ground wire 

to a ground rod or your ground source. 

Note: Proper installation is required for the grounding wire to 

achieve its highest surge capability. 

 