User’s Manual
CERIO Corporation
CS-2224-24P
PoE CS-2000 Series 2 Combo G 24 port 10/100Mbps
Web Managed PoE+ Switch
Страница 1: ...User s Manual CERIO Corporation CS 2224 24P PoE CS 2000 Series 2 Combo Gigabit 24 port 10 100Mbps Web Managed PoE Switch...
Страница 2: ...perated in a commercial environment This equipment generates uses and can radiates radio frequency energy and if not installed and used in accordance with the user s manual may cause interference in w...
Страница 3: ...3 5 Firmware Update 19 3 6 Reboot Device 20 4 Port Management 21 4 2 Port Mirroring 22 4 3 Bandwidth Control 23 4 4 Broadcast Storm Control 24 4 5 PoE 25 5 VLAN Setting 26 5 1 VLAN Mode 26 5 2 VLAN M...
Страница 4: ...11 DHCP Relay Agent 45 11 1 DHCP Relay Agent 45 11 2 Relay Server 46 11 3 VLAN MAP Relay Agent 47 12 Backup Recovery 48 13 Other Setting 49 14 Logout 51 Specifications 52...
Страница 5: ...wer device provides easy installation and the limitation of the power outlet location and offers the system relocation easily 1 1 Feature Complying with IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE...
Страница 6: ...priority tag based IP TOS based TCP UDP port bases 4 queues for per port WRR FIFS algorithm Support bandwidth control and Broadcast Storm Control Supports port mirroring and Spanning Tree functions P...
Страница 7: ...esent 10 100Mbps for data activating 3 2 Port Giga linked LED Port is linked to Giga Device the Speed Lights up LED Port is data linked the Link ACT Lights up LED The Link ACT Flashing represent 10 10...
Страница 8: ...t with 8 Port Fast Ethernet PoE Switch This switch provides automatic crossover detection functionality for any port It is simple and friendly to up link to another switch without crossover cable IP C...
Страница 9: ...comply with IEEE 802 3af IEEE802 3at and the PoE Power Max 30Watt each PSE PoE port 2 Software Configuration CS 2224 24P supports web based configuration Upon the completion of hardware installation C...
Страница 10: ...etwork and Sharing Center page Please click on the left side of Change adapter setting button Step 3 In Change adapter setting Page Please find Local LAN and Click the right button on the mouse and Cl...
Страница 11: ...perties page please Click Properties button to TCP IP setting Step 5 In Properties page to setting IP address please find Internet Protocol Version 4 TCP IPv4 and double click or click Install button...
Страница 12: ...to complete the fixed computer IP setting Step 7 Open Web Browser Without a valid certificate users may encounter the following problem in IE7 when they try to access system s WMI https 192 168 2 200...
Страница 13: ...nto the management page as follows please enter Username and password Default IP Address 192 168 2 200 Default Username and Password Management Account Root Account Username root Password default Afte...
Страница 14: ...change the user name and the password Please click Management setup Authentication Configuration Login as administrator user is root and the password is allowed to change its own password Username Man...
Страница 15: ...e your changes 3 2 System IP Configuration Here are the instructions for how to setup the local IP Address and Netmask Please click Management setup System IP Configuration System IP Configuration The...
Страница 16: ...mic IP This configuration type is applicable when the CS 2224 24P is connected to a network with the presence of a DHCP server all related IP information will be provided by the DHCP server automatica...
Страница 17: ...Provide description of the system Firmware version Show currently the CS 2224 24P of system software version and software date Set login Time out set Idle Time 1 30 Minutes Click Save button to save...
Страница 18: ...ult button to reset back to the factory default settings and expect Successful loading message Then click Reboot button to activate Recover switch default setting excluding the IP address User name an...
Страница 19: ...e new features or bugs fix It takes around 2 minutes to upgrade due to complexity of firmware To upgrade system firmware click Browse button to locate the new firmware and then click Upgrade button to...
Страница 20: ...This function allows user to restart system with existing or most current settings when changes are made Click Reboot button to proceed and take around one minute to complete Please click Management s...
Страница 21: ...gotiation enable disable Auto Negotiation Speed 10M 100M or 1000M mode for the selected port Duplex Full or Half Duplex mode for the selected port Pause enable disable for the selected port Backpressu...
Страница 22: ...traffic RX TX or TX RX from Source port to Destination port for analysis Please click Port Management Port Mirroring Destination port you can choose port 1 to port 26 Source port by clicking the chec...
Страница 23: ...o you can choose port 1 to port 26 TX Rate set the transmission rate of the selected port 0 Full speed 1 255 Specified bandwidth RX Rate set the receiving rate of the selected port 0 Full speed 1 255...
Страница 24: ...hich is allowed to enter each port in one time unit One time unit is 50us for Gigabit speed 500 us for 100Mbps speed and 5000us for 10Mbps speed Please click Port Management Broadcast Storm Control Th...
Страница 25: ...Management PoE Configuration Enable POE of the port is able to supply power to the attached PD Powered Device PSE Current Minimum Output Power The status of the port current and minimum output power P...
Страница 26: ...AN Setting 5 1 VLAN Mode There are two VLAN modes Port Based VLAN and Tag Based VLAN Please click VLAN Setting VLAN mode Click Change VLAN mode button to select the mode Click Next Enter the settings...
Страница 27: ...ag for egress packets Click Save to confirm and finish the setting 1 Link partner is a network interface card it probably cannot recognize the VLAN tag In this case it is strongly recommended the netw...
Страница 28: ...5 2 VLAN Member Setting Tag Based You can select a port group Please click VLAN Setting VLAN Member...
Страница 29: ...ble Delete Select a VID in the table and then press this button to remove a VID entry from the table Save Modify the existing VID entry select VID and then press the button The Port VID map and tag VL...
Страница 30: ...lti to 1 setting Destination Port No Choose a port of Destination Port No Current Setting Display currently set of Destination port No information Disable Port choose the port which you don t want to...
Страница 31: ...6 Per Port Counter You can read the transmitting and receiving packet of the connecting port Please click Per Port Port Counter...
Страница 32: ...ll Information 7 QoS Setting Quality of Service QoS prioritizes network traffic and manages available bandwidth so that the most important traffic goes first QoS is implemented as rules or policies th...
Страница 33: ...Q1 low priority queue Weight Round Robin set the ratio of the transmitting packet for the low priority to high priority When the queue weight is set to 0 it will be treated as 8 The low wieght and hig...
Страница 34: ...of per port by different bases Please click QoS Setting Port 802 1p IP DS based As long as any of three COS schemes 802 1p IP TOS DS or Port Base is mapped to high the data packet will be treated as...
Страница 35: ...UDP port number First in First out Discard High Priority or Law Priority to control the incoming packet The Class of Service for TCP UDP port number allows the network administrator to assign the spec...
Страница 36: ...is means 65530 65531 65534 and 65535 are all taken into account UDP TCP port 65535 and mask 0 this means only 65535 is taken into account TCP UDP Port QoS function When the override item is selected t...
Страница 37: ...ly allow MAC address on the access control list The single port you can setting three MAC address MAC Address Enter MAC address Select Select Port to binding MAC address you can select 1 26 port Bindi...
Страница 38: ...s function of per port Please click Security Service Protocol Filter Function setting Disable Enable the function Port Filtering Rule The outgoing packet with selected protocol will be either forwarde...
Страница 39: ...e secure ports which you want Click Save to confirm and finish the setting 1 The secure WAN port should be set at the physical port which is connected to the server 2 Once this function is enabled the...
Страница 40: ...one network segment in the STP becomes unreachable the spanning tree algorithm reconfigures the spanning tree topology and reestablishes the link by activating the standby path Without spanning tree i...
Страница 41: ...on message should be deleted Forward Delay Provides the length of time that bridges should wait before transitioning to a new state after a topology change If a bridge transitions too soon not all net...
Страница 42: ...multiple Ethernet ports together to form a logical aggregation group To upper layer entities all the physical links in an aggregation group are a single logical link Link aggregation is designed to i...
Страница 43: ...Control Protocol LACP a mechanism for allowing ports on both sides of a redundant link to configure themselves into a trunk link aggregate link without the need for manual configuration of the ports...
Страница 44: ...to its basic functions Static switch and switch between must be fixed and setting Link Aggregation Group LAG function LACP switch sides set to LACP mode The ports on the switch through asking way to...
Страница 45: ...ay agent DHCP clients communicate with a DHCP server on another subnet to obtain configuration parameters Thus DHCP clients on different subnets can contact the same DHCP server for ease of centralize...
Страница 46: ...nsert additional information to identify the client s point of attachment You can select the function Disable or Enable Click Save to confirm and finish the setting 11 2 Relay Server Enter DHCP Server...
Страница 47: ...Click Save to confirm and finish the setting 11 3 VLAN MAP Relay Agent Please click DHCP Relay Agent VLAN MAP Relay Agent...
Страница 48: ...0 number Map Server IP If setting the completed of Relay Server function The Map server IP you can select IP address Click Save to confirm and finish the setting 12 Backup Recovery Please click Trunki...
Страница 49: ...Download to confirm the setting Recovery Selects a file and key in the password Click Update to confirm the setting 13 Other Setting The Update password is by login password the login default password...
Страница 50: ...me VLAN Striding and IGMP Snooping etc Please click Other Setting Output Queue Aging Time Choose Aging time is 200 400 600 800ms or disable etc The output queue aging function allows the administrator...
Страница 51: ...rt No matter whether the destination port is in the same VLAN group IGMP Snooping V1 V2 You can choose IGMP Snooping disable or enable function After enable IGMP will use both V1 and V2 function If en...
Страница 52: ...Cat 3 or up 100BASE TX UTP Cat 5 or up 1000BASE T UTP Cat 5 or up Transmission Method Store and Forward MAC Address Table 4K Built in Buffer 3 5Mbits Data Transfer Rate 10 100Mbps Half duplex 20 200Mb...
Страница 53: ...t PoE Device connected for all ports 15 Watt max with no PoE Device connected Power Requirement AC 90 260VAC 50 60Hz Auto sensing Power Requirement Operating Temperature 0 to 50 C Storage Temperature...