![Cepex CSP-050 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/cepex/csp-050/csp-050_instructions_2583349002.webp)
Data represented test results in zero wind. Adjust for local conditions. Radius may
be reduced up to 25% with adjustment screw (this may alter the uniformity of
spray pattern).
Optimum performance is shown in bold type.
CSP-050 Nozzle Performance Data
Pressure Radius
Flow
Precip in/hr
Nozzle
PSI
ft.
GPM
.7 5
30
40
50
15'
16'
17'
0.64
0.75
0.85
0.55
0.56
0.57
0.63
0.65
0.65
1. 0
30
40
50
18'
19'
19'
0.85
1.0
1. 1
0.51
0.53
0.59
0.58
0.62
0.68
1. 5
30
40
50
21'
22'
22'
1. 3
1.5
1. 7
0.57
0.60
0.68
0.66
0.69
0.78
2.0
30
40
50
24'
25'
25'
1. 7
2.0
2. 3
0.57
0.62
0.71
0.66
0.71
0.82
2.5
30
40
50
27'
28'
28'
2. 2
2.5
2. 8
0.58
0.61
0.69
0.67
0.71
0.79
3. 0
30
40
50
30'
31'
31'
2. 5
3.0
3. 4
0.53
0.60
0.68
0.62
0.69
0.79
4.0
30
40
50
33'
34'
34'
3. 7
4.0
4. 3
0.65
0.67
0.72
0.76
0.77
0.83
5. 0
30
40
50
36'
37'
37'
4. 7
5.0
5. 3
0.70
0.70
0.75
0.81
0.81
0.86
Note:
All precipitation rates calculated for 180 degree operation.
For the precipitation rate for a 360 degree sprinkler , divide by 2.
CSP-050 Nozzle Performance Data – Metric
Pressure
Radius
Flow
Precip mm/hr
Nozzle Bars kPa
m
m
3
/hr l/min
.75
1.7
2.0
2.5
3.0
3.5
3.8
172
200
248
303
352
379
4. 3
4. 6
4.9
5. 2
5. 2
5.5
0.13
0.14
0.16
0.18
0.19
0.20
2. 2
2. 4
2.7
3. 0
3. 2
3. 4
14
14
13
13
14
13
17
16
15
15
17
15
1.0
1.7
2.0
2.5
3.0
3.5
3.8
172
200
248
303
352
379
5. 2
5. 5
5.5
5. 8
5. 8
6. 1
0.18
0.19
0.21
0.23
0.24
0.25
3. 0
3. 2
3.5
3. 8
4. 1
4. 2
13
13
14
14
15
14
15
15
16
16
17
16
1.5
1.7
2.0
2.5
3.0
3.5
3.8
172
200
248
303
352
379
6. 1
6. 4
6.4
6. 7
6. 7
7. 0
0.27
0.29
0.32
0.36
0.39
0.40
4. 5
4. 8
5.4
6. 0
6. 4
6. 7
15
14
16
16
17
16
17
16
18
18
20
19
2. 0
1.7
2.0
2.5
3.0
3.5
3.8
172
200
248
303
352
379
7. 0
7. 3
7.3
7. 6
7. 6
7. 9
0.34
0.37
0.42
0.48
0.53
0.56
5. 6
6. 2
7.1
8. 0
8. 8
9. 3
14
14
16
17
18
18
16
16
18
19
21
20
2.5
1.7
2.0
2.5
3.0
3.5
3.8
172
200
248
303
352
379
7. 9
8. 2
8.2
8. 5
8. 5
8. 8
0.46
0.49
0.54
0.59
0.63
0.65
7. 6
8. 1
9.0
9. 8
10.5
10.9
15
14
16
16
17
17
17
17
18
19
20
19
3.0
1.7
2.0
2.5
3.0
3.5
3.8
172
200
248
303
352
379
8. 8
9. 1
9.1
9. 4
9. 4
9. 8
0.51
0.56
0.64
0.72
0.78
0.82
8. 5
9. 3
10.6
12.0
13.1
13.7
13
13
15
16
18
17
15
15
18
19
20
20
4.0
1.7
2.0
2.5
3.0
3.5
3.8
172
200
248
303
352
379
9. 8
10.1
10.1
10.4
10.4
10.7
0.80
0.83
0.89
0.94
0.98
1.00
13.3
13.8
14.8
15.7
16.3
16.7
17
16
18
17
18
18
19
19
20
20
21
20
5.0
1.7
2.0
2.5
3.0
3.5
3.8
172
200
248
303
352
379
10.7
11. 0
11.0
11. 3
11. 3
11. 6
1.02
1.06
1.11
1.17
1.21
1.23
17.0
17.6
18.5
19.4
20.1
20.5
18
18
18
18
19
18
21
20
21
21
22
21
Note:
All precipitation rates calculated for 180 degree operation.
For the precipitation rate of a 360 degree sprinkler , divide by 2.
Nozzle Installation:
1. Insert the plastic key end of the wrench into the
lifting socket of the sprinkler and turn 90°. Pull
the riser up to gain access to the nozzle socket.
2. Using the hex key of the wrench, turn the radius
adjustment screw counterclockwise to be sure
it is not blocking the nozzle socket opening. If
a nozzle is already installed, it can be removed
by backing out the adjustment screw and
turning on the water, or by prying outward
under the nozzle.
3. Slip the desired nozzle into the nozzle socket.
Note that the socket is angled up 25° so that
the nozzle range screw threads directly down.
Then tighten the nozzle range screw. The arrow
on the rubber cover will always indicate the
location of the nozzle and direction of the water
flow when the sprinkler is retracted.
Removing Filter Screen
for Cleaning
Proper Installation
Height
CSP-050
Gear Driven Sprinklers