5.1.2 Door
adjustment
In order for your stove to burn at its best efficiency, the door must provide a perfect seal
with the firebox. Therefore, the gasket should be inspected periodically making sure to
obtain an air tight fit. Air tightness can be improved with a simple latch mechanism
adjustment. To adjust:
1. Remove the lock pin (spring pin) by pulling and turning it using pliers.
2. Turn the handle counter clock wise one turn to increase pressure.
3. Re-install the lock pin (spring pin) with a small hammer.