Century FW2600 Installation and Operation Manual
37
Good System Design
Inside chimneys are preferred because
even when no fire is burning, there is
normally upward flow in the system.
Inferior System Design
Outside chimneys are a problem because
when no fire burns they will go into cold
backdraft if the stove is installed low in the
house.
8.4.2 Why the chimney should penetrate the highest heated space
When it is cold outside, the warm air in the house is buoyant so it tends to rise. This
tendency of warm air to rise creates a slight pressure difference in the house. Called ‘stack
effect’, it produces a slightly negative pressure low in the house (relative to outside) and a
slightly positive pressure zone high in the house. If there is no fire burning in a heater
connected to a chimney that is shorter than the warm space inside the house, the slight
negative pressure low in the house will compete against the desired upward flow in the
chimney.
There are two reasons why the
chimney in the house at right will
cold backdraft when it is cold
outside and there is no fire
burning in the stove. First, the
chimney runs up the outside of the
house, so the air in it is colder and
denser than the warm air in the
house. And second, the chimney
is shorter than the heated space
of the house, meaning the
negative pressure low in the
house will pull outside air down
the chimney, through the stove
and into the room. Even the finest
stove will not work well when
connected to this chimney.
Содержание FW2600
Страница 8: ...Century FW2600 Installation and Operation Manual 8 ...
Страница 29: ...Century FW2600 Installation and Operation Manual 29 Clearances to combustible materials and floor protection ...
Страница 32: ...Century FW2600 Installation and Operation Manual 32 Clearances for shield construction ...
Страница 43: ...Century FW2600 Installation and Operation Manual 43 Installation on the bottom AC01336 ...
Страница 49: ...Century FW2600 Installation and Operation Manual 49 Appendix 5 Exploded Diagram and Parts List ...