![Century Heating CW2500 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/century-heating/cw2500/cw2500_installation-and-operation-manual_2583201026.webp)
CW2500 Insert Installation and Operation Manual
26
7 Safety Information
7.1 Summary of Installation Cautions and Warnings
•
THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE
APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER
MEDIA (OWNER’S MANUAL, CATALOGUES, FLYERS, MAGAZINES AND/OR WEB
SITES).
•
MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING
COMPONENTS MAY RESULT IN HAZARDOUS CONDTIONS. WHERE ANY SUCH
CHANGES ARE PLANNED, STOVE BUILDER INTERNATIONAL INC. SHOULD BE
CONTACTED IN ADVANCE.
•
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN
WRITING BY THE TESTING AUTHORITY VIOLATES CSA B365 (CANADA), AND ANSI
NFPA 211 (USA).
•
CONNECT THIS INSERT ONLY TO A LISTED STAINLESS STEEL CHIMNEY LINER FOR
USE WITH SOLID FUEL.
•
IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE ROOM.
•
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION
DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION.
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
•
THE INSERT AND ITS STAINLESS STEEL CHIMNEY LINER ARE TO BE INSTALLED
ONLY WITHIN A LINED MASONRY CHIMNEY AND MASONRY FIREPLACE CONFORMING
TO BUILDING CODES FOR USE WITH SOLID FUEL. DO NOT REMOVE BRICKS OR
MORTAR FROM THE EXISTING FIREPLACE WHEN INSTALLING THE INSERT.
7.2 Regulations Covering Insert Installation
When installed and operated as described in these instructions, the CB2500 wood insert is
suitable for use in residential installations. The CB2500 wood insert is not intended for
installation in a bedroom.
The construction of the masonry hearth must comply to NFPA 211, CAN/CSA A405
(Design and Construction of Masonry Chimneys and Fireplaces) or to National Building
Code of Canada.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and
Equipment and the CSA C22.1 Canadian National Electrical Code are to be followed in the
absence of local code requirements. In the USA, the ANSI NFPA 211 Standard for
Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances and the ANSI NFPA 70
National Electrical Code are to be followed in the absence of local code requirements.
This insert must be installed with a continuous chimney liner of 6” diameter extending from
the insert to the top of the chimney. The chimney liner must conform to the Class 3
requirements of ULC S635, Standard for Lining Systems for Existing Masonry or Factory-
built Chimneys and Vents, or CAN/ULC S640, Standard for Lining Systems for New
Masonry Chimneys or UL 1777, Standard for Chimney Liners.
NOTE: The Insert is not approved for use with a so-called “positive flue connection” to the
clay tile of a masonry chimney.
Содержание CW2500
Страница 8: ...CW2500 Insert Installation and Operation Manual 8 ...
Страница 37: ...CW2500 Insert Installation and Operation Manual 37 Clearances for wall and ceiling shield construction ...
Страница 41: ...CW2500 Insert Installation and Operation Manual 41 ...
Страница 57: ...CW2500 Insert Installation and Operation Manual 57 Appendix 4 Exploded Diagram and Parts List ...