background image

5

S190006

Clearance to Combustibles

Back  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2” (51 mm)
Sides  . . . . . . . . . . . . . . . . . . . . . . . . . . . .6” (153 mm)
Floor   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0” (0 mm)
Top  . . . . . . . . . . . . . . . . . . . . . . . . . . . .24” (610 mm)

Hearth

A hearth is not mandatory, but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which does not obstruct heater openings.

Electric Specifications

Voltage  . . . . . . . . . . . . . . . . . . . . . . . .120V AC/60Hz
Total Amps  . . . . . . . . . . . . . . . . . . . . . . .12.20 Amps
Total Watts . . . . . . . . . . . . . . . . . . . . . . . .1460 Watts
Heater Ratings  . . . . . . . . . . . . . . . . . . . .1300 Watts

Electrical Connection

A 15 Amp, 120 Volt, 60 Hz circuit with a properly
grounded outlet is required. Preferably, the appliance
will be on a dedicated circuit as other appliances on
the same circuit may cause the circuit breaker to trip
or the fuse to blow when the heater is in operation.

The unit comes standard with a 6’ (1.8m) long three
wire cord, exiting from the rear of the stove. Plan the
installation to avoid the use of an extension cord. If an
extension cord must be used, it must be a minimum
14AWG, three wire with grounding type plug connector
and rated not less than 1875 Watts. The cord shall not
be more than 20’ (6m) in length.

WARNING: Electrical outlet wiring must
comply with local building codes and
other applicable regulations to reduce the
risk of fire, electrical shock and injury to
persons.

WARNING: Do not use this stove if any
part of it has been under water.
Immediately call a qualified service tech-
nician to inspect the stove and replace
any part of the electrical system.

Fan Kit Installation

When installed, the heater must be elec-
trically connected and grounded in accor-
dance with local codes, or in th absence
of local codes, with ANSI/NFPA No. 70.

NOTE: 110/120 electric power is required to operate
blower (fan). 

Be sure to leave sufficient excess wire in case minor
adjustments are required.

Any electrical re-wiring of this fan must be done by a
qualified electrician.

Turn off all power before installation.

CAUTION: Be careful not to touch or bend the flame
generator.

1. Remove panel from back of pedestal

2. Install the fan through the opening at the back of

the pedestal. Place fan assembly as far forward as
possible, inserting long flange through slot in front
panel. (Fig. 1) 

3. Use two screws provided to secure fan assembly to

base of pedestal. (Fig. 2)

4. From front of unit, attach brass handle to front of

fan assembly flange. (Fig. 3)

5. Plug in grounded service cord to a convenient wall

receptacle.

6. Replace rear panel in pedestal.

Slot

ST824

Fig. 1 Insert flange through slot in front panel.

Содержание BANFF HES80

Страница 1: ...v 0 INSTALLER CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY AN ELECTRICAL SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE FOR YOUR SAFETY Service must be performed by a qual ified service agency DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQU...

Страница 2: ...Failure to follow these instructions may result in a possible electric shock fire hazard and will void the warranty Installation Instructions General 3 Locating Your Stove 3 Stove Dimensions 4 Clearance to Combustibles 5 Hearth 5 Electrical Specifications 5 Electrical Connections 5 Fan Kit Installation 5 Service Instructions Replacing Light Bulbs 6 Maintenance of Motors 6 Electrical Wiring Diagram...

Страница 3: ...s only 13 This appliance when installed must be electrically grounded in accordance with local codes with the current CSA C22 1 Canadian Electrical codes or for USA installations follow local codes and the National Electric Code ANSI NFPA No 70 14 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock fire or damage the appliance 15 T...

Страница 4: ...22 572 mm 24 616 mm 14 362 mm 14 362 mm 27 708 mm 13 343 mm 4 S190006 Stove Dimensions ...

Страница 5: ...able regulations to reduce the risk of fire electrical shock and injury to persons WARNING Do not use this stove if any part of it has been under water Immediately call a qualified service tech nician to inspect the stove and replace any part of the electrical system Fan Kit Installation When installed the heater must be elec trically connected and grounded in accor dance with local codes or in th...

Страница 6: ...ocated under the log set ember bed For convenience if one of the bulbs burns out it may be a good idea to replace both of the light bulbs 1 Turn off power to the unit by unplugging the power cord 2 Let stove cool if it has been operating 3 Remove rear access panel from back of pedestal to expose light bulbs 6 S190006 Fan Assembly ST818 Fig 2 Secure fan assembly to base of pedestal Fig 3 Attach bra...

Страница 7: ... the On Off switch to meet this requirement 7 If repairing or replacing any electrical component or wiring the original wire routing color coding and securing locations must be followed WIRE 1 BLACK WIRE 2 BLACK WIRE 3 BLACK HOT SPEED CONTROL REMOTE RECEIVER WIRE 4 BLACK BLACK WIRE RED LINE OUTPUT WHITE WIRE MOTOR FLAME GENERATOR RED WIRE BLACK WIRE WIRE 7 WHITE WIRE 8 WHITE HEATER MOTOR WIRE 9 WH...

Страница 8: ...ducts aux présentes nommée la Société garantit votre nouveau poêle électrique Northern Flame contre tous défauts de fabrication et de matières premières pour une période d un an à compter de la date d installa tion sujet aux conditions et limitations suivantes 1 Le poêle electrique doit être installé par un entrepreneur de service autorisé et compétent Il doit être installé et utilisé en tout temp...

Отзывы: