8
Function
Constantly
monitors
the
spring
balance
of
the
garage
door
and
warns
the
user
when
door
is
out
of
balance.
Courtesy
lamp
will
triple
blink
every
15
sec
once
imbalance
is
excessive.
At
this
time
the
garage
door
should
be
serviced
by
a
suitably
qualified
technician.
To
Enable
Select
Dip
4
to
the
“ON”
position
Function
The
LED
(13
‐
I)
provides
Opener
status
information.
Indication
Glow
Solid
–
Opener
has
reached
close
limit
position
Slow
Blink
–
Opener
has
reached
open
limit
position
Rapid
Blink
–
Opener
Learning
new
drive
force
values
Intermittent
Blink
–
Sleep
Mode
Function
Safety
Beams
constantly
monitor
for
persons
or
objects
which
may
cross
the
path
of
a
moving
garage
door.
The
Opener
will
commence
to
Safety
Reverse
when
the
Safety
Beams
become
momentarily
or
permanently
interrupted
during
a
closing
movement.
The
Opener
will
support
the
connection
of
2
or
4
wire
Safety
Beams.
Fault
Indication
Courtesy
Lights
will
double
blink
and
the
Opener
will
not
move
if
the
Safety
Beams
are
faulty
or
misaligned.
Override
Press
and
hold
the
Run
Button
(Fig.6A
or
7
‐
A)
until
the
Opener
has
reached
the
fully
closed
position
To
Enable
Select
Dip
2
to
the
“ON”
position
(Fig.7
‐
G)
Connection
2
Wire
Beams
–
Select
jumper
(Fig.7
‐
H)
to
“1
‐
2”
position
and
connect
the
wires
as
per
Fig.8
‐
A
4
Wire
Beams
–
Select
jumper
(Fig.7
‐
H)
to
“2
‐
3”
position
and
connect
wires
as
per
Fig.8
‐
B
Function
Allows
speed
adjustment
of
the
Opener
to
best
suit
the
door
type.
(Only
available
in
A
Mode)
Adjustment
Stop
Opener
midway
between
open
and
close
position.
Press
and
hold
Learn
Button
(Fig.6
‐
A
or
7
‐
A)
until
LED
(Fig.7
‐
I)
begins
to
rapid
blink.
Rotate
the
Speed
Adjust
Pin
(Fig.7
‐
D)
while
opener
is
running
‐
clockwise
to
increase
speed
and
anti
clockwise
to
decrease
speed.
Speed
may
only
be
adjusted
while
the
Opener
is
traveling
between
limits.
Adjustment
function
will
close
out
automatically
once
either
one
of
the
limits
has
been
reached
Function
The
following
accessories
may
be
connected;
a.
2
wire
Safety
Beams
(Fig.8
‐
A)
b.
N.O.
24V
DC
4
wire
Safety
Beams
(Fig.8
‐
B)
c.
24V
DC
universal
receiver
(Fig.8
‐
C)
d.
N.O.
momentary
(dry)
contact
wall
switch
(Fig.8
‐
D)
e.
240V
relay
driven
courtesy
light
–
output
24VDC,
150mA
maximum
(Fig.7
‐
J)
Function
Disables
push
button
functionality
in
order
to
provide
utmost
security
whilst
user
is
absent
for
extended
periods
of
time
To
Enable
Press
button
4
of
Mass
Learned
transmitter
Courtesy
Light
4
x
blink
to
indicate
Opener
has
entered
Vacation
Mode
To
Disable
Momentarily
press
either
button
1
or
button
2
of
a
Mass
Learned
transmitter
19.
Safety
Beams
20.
Speed
Control
21.
Terminal
Connections
22.
Vacation
Mode
18.
LED
Indicator
SETTINGS
AND
ADJUSTMENTS
17.
Door
Service
monitor
Содержание RDO-10A
Страница 1: ...1...
Страница 2: ...2...
Страница 9: ...9 A Learn B Run...
Страница 10: ...10 A B C D E F G H I J...
Страница 11: ...11 EXPLODED PARTS VIEW...