8. Electrical setup

1.  Ensure that all low voltage systems (less than 42.4V) are 
 

suitably protected from damage, by disconnecting all  

 

sources of power such as chargers and batteries before 

 

doing any work.

2.  All electrical work must be carried out according to the 
 

requirements of all applicable local electrical codes.(It is 

 

recommended that a licensed electrical contractor perform 

 

such work.)

 

roadside to accommodate the feeder. After the loop and feeder 

 

wires have been placed in the slot, the slot must be filled with an 

 

epoxy compound or bitumen filler.

7. Mounting instructions

The housing of the 

FLUX 11

 is not weatherproof, and it should not be 

mounted externally. 

Simply insert the 

FLUX 11

 into the 11 pin base of the access 

control device.

Lead cable

slot

Corner stress 
relief

4mm Saw slot

Pavement surface

50mm

4mm

Saw cut

11 

1

2

3

4

5

6

7

8

10 

Loop detector base

Presence
relay 
output

Presence
relay 
output

Power 
input

Free-exit 

loop

FLUX 11
loop detector

Plug the FLUX 11 into the base

Содержание FLUX 11

Страница 1: ...FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR...

Страница 2: ...rmers or time consuming rewiring Typical uses include free exit loops safety loops closing loops for traffic barriers arming loops for access control equipment and general vehicle sensing applications...

Страница 3: ...Dipswitches 7 Reset button 1 2 3 7 9 This product was designed and built strictly for the use indicated in this documentation Any other use not expressly indicated here could compromise the service li...

Страница 4: ...l prevent the barrier from lowering Dipswitches Reset Button Run Switch Supply voltage 12V DC Model 230VAC Model Standby current 12V DC Model 230VAC model Output relay rating Detection time Indicators...

Страница 5: ...etected Automatic Sensitivity Boost ASB Switch If selected together with Presence Output the output will remain active as long as a vehicle remains on the loop The danger of using this setting is that...

Страница 6: ...loop installation 1 The FLUX 11 should be installed in a weatherproof location such as the inside of a traffic barrier as close to the loop as possible 2 The loop and feeder should be constructed from...

Страница 7: ...vent damage to the wire on the corners The slot should be about 4mm wide and 30mm to 50mm deep Remember to extend the slot from one of the corners to the Support stakes 4 needed Curb Metal free zone o...

Страница 8: ...de to accommodate the feeder After the loop and feeder wires have been placed in the slot the slot must be filled with an epoxy compound or bitumen filler 7 Mounting instructions The housing of the FL...

Страница 9: ...udible tone is heard two short tones one long tone Check that there is no short circuit on the loop feeder wiring or the loop If there is no short circuit then the inductance is too small and more tur...

Страница 10: ...2072013 Sharecall 0860 CENTURION 0860 236 887 Head Office 27 11 699 2400 Sharecall Technical Support 0861 003 123 or 27 11 699 2481 from 07h00 to 18h00 GMT 2 Sharecall numbers applicable when dialed f...

Отзывы: