background image

CENTROSOLAR AG 

 Stresemannstraße 163 

 22769 Hamburg 

 

 GERMANY 

 Tel.: +49 (0)40 3910650 

 [email protected]

+

-

+

-

+

-

+

-

Solar

+

+_D

-

red

green

blue

Output

= 6A, 60V

-

-

+

-

+

+

+

-

+

-

-

+

-

+

Function of the cell-protector:

The purpose of the cell protector is to prevent overheating of the solar cells (risk of hotspot) when the solar module is partial 
shaded. This is achieved by the diodes on the circuit board. By standard aluminium framed glass modules these diodes are 
located in the junction box on the backside of the modules.
The bypass diodes can be damaged by power surges and lightning. By fitting into the cap any replacement would be impos-
sible. Therefore the bypass diodes at the M-Series modules are installed in the external cell-protector. Additionally a diode is 
incorporated on the PC-board to prevent reverse current. Depending on the kind of connection, this protection can be used.
However, the Schottky diode produces a voltage drop of about 0.6V.

Connection graphics

Cell protector required only for modules with 3-wire connection cable!

12V: Parallel connection of 12V solar modules

Circuit diagram cell-protector V2.2

24V: Serial connection of 12V solar modules

12 V

12 V

12 V

12 V

12 V

12 V

12 V

12 V

12 V

Cell-

 

pr

otector

Cell-

 

pr

otector

Cell-

 

pr

otector

Cell-

 

pr

otector

Cell-

 

pr

otector

Cell-

 

pr

otector

Cell-

 

pr

otector

12 V battery system

24 V battery system