EKO-CKS P UNIT

HEATING TECHNIQUE

Centrometal d.o.o.

 - Glavna 12, 40306 Macinec, Croatia, tel: +385 40 372 600, fax: +385 40 372 611

TU-R-CKSP-3-2022-v1.12v-ENG

TECHNICAL INSTRUCTIONS

Description and using of EKO-CKS P UNIT 
controller

- USER

THE FIRST START-UP MUST BE DONE BY AUTHORIZED PERSON,
OTHERWISE PRODUCT WARRANTY IS NOT VALID.

ENG

Содержание EKO-CKS P UNIT controller

Страница 1: ...0306 Macinec Croatia tel 385 40 372 600 fax 385 40 372 611 TU R CKSP 3 2022 v1 12v ENG TECHNICAL INSTRUCTIONS Description and using of EKO CKS P UNIT controller USER THE FIRST START UP MUST BE DONE BY...

Страница 2: ...turning the main switch the screen should not be pressed by nger If the screen when you turn the main switch is pressed on the screen labeled Firmware update regulation is in software update that can...

Страница 3: ...1 2 3 4 5 LEGEND 1 Time Date 2 Display selection Main menu Main screen 3 Dropdown menu 4 State of the current boiler status working phase 5 Boiler Start Stop 1 2 3 4 5 Technical instructions REGULATIO...

Страница 4: ...IOUS SCREEN Button NEXT SCREEN Button OK Navigation buttons LEFT RIGHT UP DOWN Button DELETE Button FACTORY SETTINGS Button INFORMATION Button COPY Button PASTE MAIN MENU The main menu is used to sele...

Страница 5: ...with current temperature Heating circuit Room thermostat Next to the room thermostat symbol bright blue circle the room thermostat has requested for operating the pump the pump does not work if you h...

Страница 6: ...OFF Alternative boiler FREEZE ON Auxiliary boiler CM GSM module network status Regulation is connected with web portal internet supervision is possible Regulation is not connected with web portal inte...

Страница 7: ...ic ash removal system out of the boiler combustion chamber spiral Additional equipment 8 Ash box if is installed 9 Automatic ash removal system out of the flue gas chamber spiral Additional equipment...

Страница 8: ...ional equipment managment by dropdown menu 3 By pressing button for boiler operation 1 on display will be displayed dropdown menu By pressing button for additional equipment managment 2 on display wil...

Страница 9: ...er operation 1 on display will be displayed dropdown menu By pressing button for regulator 2 on display will be displayed heating circuit preview 2 1 2 1 Cascade managment by dropdown menu if is insta...

Страница 10: ...power 2 P3 power 3 P4 power 4 P5 power 5 A0 extinguishing waits for flame disappearing A1 fan blowing A2 pause the boiler is waiting for the conditions to start PF0 operation after el power failure PF...

Страница 11: ...ow for boiler start confirmation Press OK to confirm boiler start BOILER STOP For boiler stop is neccesary to press ON OFF button After pressing ON OFF button on display will be displayed window for b...

Страница 12: ...in this box are located available options for choose 5 Parameter value in this box are shown currently write value 6 Currently adjusted value in this box are shown currently adjusted value of paramet...

Страница 13: ...ut which components are selected in point 1 1 4 Type these components will be start with work with duration of 60 minutes 2 Now is possible to start with cleaning Pay attention to errors and warnings...

Страница 14: ...adjustment Factory adjustmen 100 Minimal adjustment value 20 Maximal adjustment value 100 1 1 3 BURNER FAN In this parameter is possible to adjust percentage of burner fan work in cleaning option if...

Страница 15: ...ossible selection Cyclone if is installed and configured Burner fan Ash removing if is installed and configured Flue gas box conveyor if is installed and configured Every compontent can be selected in...

Страница 16: ...onnection method CRO hydraulic crossover C connection method CRO Sensor hydraulic crossover sensor X only if DHW domestic hot water exist on heating system must be configured like additional equipment...

Страница 17: ...ER TEMPERATURE A X 2 2 A BUFFER TANK TEMPERATURE if is installed and configured In this parameter is possible to adjust accumulation tank temperature Possible adjustment Factory adjusted 80 C Minimal...

Страница 18: ...imal adjustment value 75 C 2 4 A dTBUF off Difference of buffer tank temperature for boiler shut down pause if is installed and configured Possible adjustment Factory adjusted 10 C Minimal adjustment...

Страница 19: ...ature Possible adjustment Factory adjusted 50 C Minimal adjustment value 10 C Maximal adjustment value 70 C 2 6 A DIFFERENCE OF DOMESTIC HOT WATER TEMPERATURE if is installed on heating installation a...

Страница 20: ...B X 2 1 B BOILER TEMPERATURE In this parameter is possible to adjust boiler temperature Possible adjustment Factory adjusted 80 C Minimal adjustment value 65 C Maximal adjustment value 90 C Technical...

Страница 21: ...ature Possible adjustment Factory adjusted 50 C Minimal adjustment value 10 C Maximal adjustment value 70 C 2 3 B DIFFERENCE OF DOMESTIC HOT WATER TEMPERATURE if is DHW configured This parameter can t...

Страница 22: ...adjusted automatic by displayed formula 2 2 C HYDRAULIC CROSSOVER TEMPERATURE In this parameter is possible to adjust hydraulic crossover temperature Possible adjustment Factory adjusted 75 C Minimal...

Страница 23: ...ature Possible adjustment Factory adjusted 50 C Minimal adjustment value 10 C Maximal adjustment value 70 C 2 4 C DIFFERENCE OF DOMESTIC HOT WATER TEMPERATURE if is DHW configured This parameter can t...

Страница 24: ...times are turned on and work according to the settings inTable 1 Table 2 Scheduled starting times are turned on and work according to the settings in Table 2 Table 3 Scheduled starting times are turne...

Страница 25: ...ess this key now you have copied the setting of that day and now will show button PASTE It is necessary to press the day for which you want this settings and press the button PASTE After that the same...

Страница 26: ...d off Table 1 Scheduled starting times are turned on and work according to the settings inTable 1 Table 2 Scheduled starting times are turned on and work according to the settings in Table 2 Table 3 S...

Страница 27: ...ess this key now you have copied the setting of that day and now will show button PASTE It is necessary to press the day for which you want this settings and press the button PASTE After that the same...

Страница 28: ...of the error warning information The first press on the field error warning information field is indicated in addition to see and date generated errors warnings information The second press on the se...

Страница 29: ...reading from ue gas sensor FLUE GAS TEMPERATURE TOO HIGH E4 Boiler status Safety thermostat interrupt el power because of too high temperature in boiler wait until the boiler temperature drops below m...

Страница 30: ...n to the junction box cold connection or invalid sensor INCORRECT RETURN LINE SENSOR E104 Boiler status Incorrect bu er tank sensor up Possible causes Interruption on el connection between sensor and...

Страница 31: ...sible causes Problem with entry tension cyclone fan bad el connections or inverter is invalid CYCLONE INVERTER ERROR E113 Boiler status Burner inverter error Possible causes Problem with entry tension...

Страница 32: ...2_8 Thermal overload feeder screw 1 motor Pellet feeding conveyors from the seasonal tank if is installed additional equipment THERMAL OVERLOAD FEEDER SCREW 1 MOTOR E123_1 Control error mod 2 feeder s...

Страница 33: ...too high mod 3 feeder screw 3 Pellet feeding conveyors from the seasonal tank if is installed additional equipment ERROR CURRENT TOO HIGH MOD 3 FEEDER SCREW 3 E124_4 Error asymmetry mod 3 feeder screw...

Страница 34: ...e man COMMUNICATION ERROR WITH EXT BOARD A13 E125_7 Call service man COMMUNICATION ERROR WITH EXT BOARD A12 E125_8 Call service man COMMUNICATION ERROR WITH EXT BOARD A0 E125_9 Call service man COMMUN...

Страница 35: ...normally Possible causes Error on ow temperature sensor of 1 heating circuit on regulator CM2K SENSOR CM2K 1 CIRCUIT E128 Boiler status Pump of 1 heating circuit work in intervention mode by heating c...

Страница 36: ...ating circuit CM2K regulator bad corrector connection to the CM2K or room corrector failure CORRECTOR CM2K 4 CIRCUIT E135 Boiler status Pump of 5 heating circuit doesn t work Boiler work normally Poss...

Страница 37: ...er work normally Possible causes Error on ow temperature sensor of 8 heating circuit on regulator CM2K SENSOR CM2K 8 CIRCUIT E142 Boiler status Pump of 8 heating circuit work in intervention mode by h...

Страница 38: ...connection between sensor and junction box connection to the junction box cold connection or invalid sensor INCORRECT RETURN LINE SENSOR W7 Boiler status Junction box temperature too high Possible cau...

Страница 39: ...Possible causes Time and date are not adjusted it stayed on factory settings WRONG TIME AND DATE INFORMATIONS INFO NAME I4_1 ASH REMOVING TURNED OFF I4_2 ASH REMOVING TURNED ON IW1_1 POWER DOWN IW1_2...

Страница 40: ...e boiler IMPORTANT To be able to stop all processes you must first turn off the boiler in the usual way by pressing and then STOP Option for boiler force shut down By pressing on OK button boiler and...

Страница 41: ...the corresponding symbols and check if the fan operates according to the selected option After pressing the STOP fan will turn off Each time you press START it becomes STOP and vice versa The display...

Страница 42: ...ove a symbol of the pellet feeding screw and will show animation falling pellet boiler 5 2 x CYCLONE additional equipment for EKO CKS P UNIT 140 430 This option allows you to check Cyclone work NOTE C...

Страница 43: ...responding symbol and check if the pump work After pressing the STOP pump will stop working Each time you press START it becomes STOP and vice versa The display will show animation of the pump 5 2 x 3...

Страница 44: ...2 x BURNER AIR CLEANING 2 only for EKO CKS P UNIT 499 560 This option allows you to check burner air cleaning 2 work It is necessary to press START next to the corresponding symbol and check if air cl...

Страница 45: ...and vice versa On display will be displayed ON marker on compressor symbol 5 2 x CONDENSATE 1 This option allows you to check work of valve for condensate drainage 1 By pressing START valve will be op...

Страница 46: ...ditional equipment 1 2 3 4 Dispenser 5 6 7 Pneumat valves Flue gas box screw 8 Regulator CM2K 5 2 x AUXILIARY BOILER This option exists only if Auxiliary boiler is selected by an authorized service te...

Страница 47: ...Dispenser 5 6 7 Pneumat valves Flue gas box screw 8 Regulator CM2K 5 2 x x CYCLONE additional equimpent for EKO CKS P UNIT 140 430 This option allows you to check Cyclone work NOTE This option will b...

Страница 48: ...r 5 6 7 Pneumat valves Flue gas box screw 8 Regulator CM2K DHW pump Cyclone Refilling Ash removing 5 2 x Additional equipment 1 2 3 4 Dispenser 5 6 7 Pneumat valves Flue gas box screw 8 Regulator CM2K...

Страница 49: ...ULATOR CM2K 2 CIRCUIT additional equipment This option allows you to check work pump and mixing valve on 2 heating circuit Note Number od heating circuit depend about installed number of CM2K modules...

Страница 50: ...s feedery screw empty this option is used for filling feeder screw By pressing START feeder screw start with work This option must be turned on until fuel start droping from feeder screw 5 4 WEIGHING...

Страница 51: ...5 5 SAVE LOAD 5 5 1 SAVE Existing saved image if exist Button for saving settings in new image Technical instructions REGULATION EKO CKS P UNIT 51...

Страница 52: ...isplayed message Successful which mean that settings are successful saved Confirm message by pressing button 4 For saving in new image is necessary to press twice on button 1 On display will be displa...

Страница 53: ...which we want to load and press on it 1 On display will be displayed message Are you sure Is necessary to confirm message 2 On display will be displayed message Successful which mean that settings are...

Страница 54: ...serviceman adjust and saved at first start up For loading of serviceman settings is necessary to choose image which we want to load and press on it 1 On display will be displayed message Are you sure...

Страница 55: ...h we want to delete and press on it 1 On display will be displayed message Are you sure Is necessary to confirm message 2 and press button for saving confirmation 3 On display will be displayed messag...

Страница 56: ...s User can t change this parameters NOTE Cyclone will be factory placed in menu 5 6 Standard equipment for boilers EKO CKS P UNIT 499 560 because cyclone is standard delivery for that boilers For boil...

Страница 57: ...available if an authorized service technician has configured MOTOR MODULES under permanent settings MOTOR MODULES pellet dosing into the burner only using a 3 phase 400 V motor If a coil is installed...

Страница 58: ...ly be selected by an authorized service technician Alarm type can only be selected by an authorized service technician factory Stop errors the relay switches on when an error occurs which stops furthe...

Страница 59: ...r does not allow its operation Manual OFF the option to switch on the alternative boiler is switched o manually RELAY will not switch ON an alternative boiler Manual ON RELAY permanently requests the...

Страница 60: ...start external control of the main boiler is switched o the state returns to ON when the schedule or external start external control of the main boiler requests operation boiler FREEZE ON if the stat...

Страница 61: ...easured Taku_kz Taku_kz Factory 6 C adjustable 1 C 15 C b Boiler main boiler is connected to the hydraulic crossover CRO sensor CONDITION 2 Ths_kz Ths_set Ths_measured Ths_kz Factory 6 C adjustable 1...

Страница 62: ...EQUIPMENT for equipment which was installed and configured by an authorized tehnician 5 7 x 1 DHW This option allow domestic hot water turning on off Factory ON Technical instructions REGULATION EKO...

Страница 63: ...djustment value 1440 min 5 7 x 2 RECIRCULATION if is configured This option allow turning on off recirculation of domestic hot water 5 7 x 4 RECIRCULATION PAUSE if is configured In this parameter is p...

Страница 64: ...this parameter NOTE Cyclone will be factory placed in menu 5 6 Standard equipment for boilers EKO CKS P UNIT 499 560 because cyclone is standard delivery for that boilers For boilers EKO CKS P UNIT 1...

Страница 65: ...ible adjustment Factory adjusted 120 min Minimal adjustment value 30 min Maximal adjustment value 360 min 5 7 x 3 ON TIME Px In this parameter is possible to adjust ash removing working time Possible...

Страница 66: ...ome parameters only This option allow preview of pneumat parameters User can t change this parameters REFILLING re lling the pellet tank with boiler from the seasonal pellet tank Possible types select...

Страница 67: ...cleaning parameters User can t change this parameters 5 7 x REGULATOR CM2K In this menu is possible to change parameters for heating circuits Number of heating circuits depend about number of installe...

Страница 68: ...off heating circuit 5 7 x x 2 VALVE TIME This parameter is available only for preview It s not possible to change this parameter 5 7 x x 3 HEATING TYPE This parameter is available only for preview It...

Страница 69: ...and outside temperature to achieve the desired room temperature Possible adjustment Factory adjusted 1 Minimal adjustment value 0 1 Maximal adjustment value 4 0 This parameter determines the influence...

Страница 70: ...ew It s not possible to change this parameter This parameter is available only for preview It s not possible to change this parameter This parameter determines the value of day room temperature Possib...

Страница 71: ...ry adjusted Minimal adjustment value 5 C Maximal adjustment value 30 0 C This option enables you to choose type of desired temperature day night or table In next page you can see how to fill a table P...

Страница 72: ...d to night temperature When passed one cycle week circle starts again from the beginning The values of a day night room temperature can be selected as is described in previous pages Day temperature Ni...

Страница 73: ...7 x 1 SMS CALL Option for turning on off sms call if is installed and configured Possible selection Factory selected OFF Possible selection ON OFF 5 7 x CASCADE Technical instructions REGULATION EKO...

Страница 74: ...his parameter 5 7 x 2 DEVICE NUMBER This option allow preview of device number adjustment User can t change this parameter 5 7 x 3 DEVICE ADRESS This option allow preview of device adress selection Us...

Страница 75: ...t change this parameter 5 7 11 5 TIME TO ON This option allow preview of time to ON adjustment User can t change this parameter 5 7 11 6 TIME TO OFF This option allow preview of time to OFF adjustment...

Страница 76: ...DIFFERENCE This option allow preview of time difference adjustment User can t change this parameter 5 7 x 8 COUNTER RESET This option allow you to reset counter Technical instructions REGULATION EKO C...

Страница 77: ...ain screen showing the status of internet supervision IMPORTANT NOTES CM WiFi box requires active DHCP server of Access Point e g router because manual setting of network parameters is not possible Fo...

Страница 78: ...nection with home network This option allows you to enter the name of WiFi home network to which you want to connect the Cm WiFi box and the boiler You must enter exact WiFi network name or else boile...

Страница 79: ...ning on off Possible selection Factory selected OFF Possible selection OFF ON Option for work mode choose Possible selection Factory selected Heating DHW Possible selection Heating DHW AUTO DHW Heat D...

Страница 80: ...ns AUTO DHW Heat DHW This mode is possible if there are heating circuit s and DHW the controller changes Heating DHW and DHW mode according to set conditions outside temperature and it automatically a...

Страница 81: ...actory selected ON Possible selection ON OFF IMPORTANT Automatically resume boiler operation after the disappearance of electric power PF phases is not possible if language selection option is turned...

Страница 82: ...s used to set the date and time It is necessary for starting times and the recording of errors warnings for the occurrence of errors warnings remembers the date and time of occurrence After setting th...

Страница 83: ...ices in statistics operation min burner fan min flue gas fan min feeder screw min heater min heater count 6 7 SOUND TYPE Sound type select one of the 10 offered sound types pump min pump count flue ga...

Страница 84: ...OFF Regulator v1 07e 140kW 7 3 LOCKING Status of screen locking A if is screen locked on display will be displayed locking informatio date time and user which is lock screen 7 4 ENCLOSURE TEMPERATURE...

Страница 85: ...two heating circuits CM2K B is installed and configurated 8 1 MANUAL TEST 8 1 1 1 CIRCUIT Option for testing elements of 1st heating circuit mixing valve START open mixing valve START close and pump S...

Страница 86: ...uit mixing valve START open mixing valve START close and pump START 8 2 1 CIRCUIT Option for turning on off first heating circuit Possible selection Factory selected ON Possible selection ON OFF 8 2 2...

Страница 87: ...low temperature according to the heating curve and outside temperature to achieve the desired room temperature Possible adjustment Factory adjusted 1 Minimal adjustment value 0 1 Maximal adjustment va...

Страница 88: ...required flow temperature in the heating circuit Possible adjustment Factory adjusted 1 Minimal adjustment value 0 1 Maximal adjustment value 5 0 8 2 4 DAY ROOM TEMPERATURE This parameter determines t...

Страница 89: ...alue 5 C Maximal adjustment value 30 0 C 8 2 6 DAY NIGHT TEMPERATURE CHOICE This option enables you to choose type of desired temperature day night or table In next page you can see how to fill a tabl...

Страница 90: ...ature When passed one cycle week circle starts again from the beginning The values of a day night room temperature can be selected as is described in previous pages Day temperature Night temperature 8...

Страница 91: ...ash box than is possible to use this option which is used for better completed fuel burning With increase value of parameter fuel will be better burn Note use only if is appear a lot of unburned fuel...

Страница 92: ...display Display can be locked only if exist profile for locking 10 2 Add user 10 4 User list When is display locked is possible to move through all menus but parameters can t be changed Technical ins...

Страница 93: ...it by pressing confirm button 2 Enter pin and confirm it After that is necessary to re entry pin and confirm it 10 3 DELETE USER 2 1 Option for delete users You need to enter the pin of the user you w...

Страница 94: ...10 4 USER LIST 11 1 CHIMNEY SWEEPER 11 CHIMNEY SWEEPER Technical instructions REGULATION EKO CKS P UNIT 94...

Страница 95: ...een and flue gases can be measured Possible selection Factory selected OFF Possible selection OFF ON 11 2 POWER This option allows the boiler to work in different powers in order to measure the flue g...

Страница 96: ...0 372 622 fax 385 40 372 621 Centrometal d o o assumes no responsibility for possible inaccuracies in this book originated typographical errors or rewriting all the pictures and diagrams are principal...