Vibration Precautions

This tool vibrates during use.  

Repeated or long-term exposure to vibration may 

cause temporary or permanent physical injury, 

particularly to the hands, arms and shoulders.  

To reduce the risk of vibration-related injury:

1.  Anyone using vibrating tools regularly or for an 

extended period should first be examined by a 

doctor and then have regular medical check-ups to 

ensure medical problems are not being caused or 

worsened from use.  Pregnant women or people who 

have impaired blood circulation to the hand, past 

hand injuries, nervous system disorders, diabetes, 

or Raynaud’s Disease should not use this tool.  

If you feel any symptoms related to vibration (such 

as tingling, numbness, and white or blue fingers), 

seek medical advice as soon as possible.

2.  Do not smoke during use.  Nicotine reduces 

the blood supply to the hands and fingers, 

increasing the risk of vibration-related injury.

3.  Wear suitable gloves to reduce the 

vibration effects on the user.

4.  Use tools with the lowest vibration when there 

is a choice between different processes.

5.  Include vibration-free periods each day of work.

6.  Grip tool as lightly as possible (while still keeping 

safe control of it).  Let the tool do the work.

7.  To reduce vibration, maintain tool as explained 

in this manual.  If abnormal vibration occurs, 

stop immediately.

 SAVE THESE INSTRUCTIONS.

SAFETY

OPERA

TION

MAINTENANCE

SETUP

Содержание 69927

Страница 1: ......

Страница 2: ...ed could result in minor or moderate injury Addresses practices not related to personal injury Symbol Property or statement PSI Pounds per square inch of pressure CFM Cubic Feet per Minute flow SCFM C...

Страница 3: ...thes jewelry or long hair increases the risk of injury to persons as a result of being caught in moving parts c Avoid unintentional starting Be sure the trigger is released before connecting to the ai...

Страница 4: ...g Many accidents are caused by poorly maintained tools There is a risk of bursting if the tool is damaged h Use only accessories that are identified by the manufacturer for the specific tool model Use...

Страница 5: ...eways during firing causing them to exit the workpiece at an unexpected point causing personal injury 18 Transport tool safely Always disconnect air supply when moving the tool Carry the tool by the h...

Страница 6: ...ous system disorders diabetes or Raynaud s Disease should not use this tool If you feel any symptoms related to vibration such as tingling numbness and white or blue fingers seek medical advice as soo...

Страница 7: ...itchable Single Sequential or Contact Trip switchable Nail Type 10 Gauge 2 3 8 3 1 4 Long 21 Angle Plastic Collated Full Head 10 Gauge 2 3 8 3 1 4 Long 28 Angle Paper Collated Clipped Head Components...

Страница 8: ...ERIOUS INJURY FROM ACCIDENTAL OPERATION Do not install a female quick coupler on the tool Such a coupler contains an air valve that will allow the air tool to retain pressure and operate accidentally...

Страница 9: ...lter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler and Plug Provides quick connection...

Страница 10: ...ne 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of use H Air Hose Connects air to to...

Страница 11: ...igger It should only fire again if the trigger is released and squeezed again The Tool should not fire if the Safety Nosepiece is not pressed against an object Single Sequential Safety Trip Mechanism...

Страница 12: ...by a qualified service technician 6 Hold the tool away or off of the workpiece The Safety Nosepiece should return to its original position Squeeze the Trigger The tool must not cycle fire If it cycle...

Страница 13: ...n and depress the Safety Nosepiece fully against the workpiece Squeeze the trigger to fire a fastener Note PREVENT DOUBLE FIRING allow the tool to recoil from the workpiece do not force it against the...

Страница 14: ...problem corrected before further use TO PREVENT EXPLOSION Lubricate only with specified lubricants Lubricate the air inlet using only pneumatic tool oil Lubricate the internal mechanism using only whi...

Страница 15: ...azine and leave it open during service The Magazine is spring loaded and may cause parts or a fastener to fly out of the Tool 1 If a fastener is jammed in the discharge area remove it with pliers 2 If...

Страница 16: ...ool empty 3 Incorrect fasteners used 4 Magazine dirty or not lubricated properly 5 Insufficient air flow 1 Clear jammed fastener according to Clearing Jams instructions 2 Reload with correct fasteners...

Страница 17: ...PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER A...

Страница 18: ...ce 38 Washer 39 Depth Adjustment Screw 40 Rubber Cover 40a Cover Clip 41 Spring Pin 42 Safe Guide 43 O ring 18 4x2 4 44 O ring 20 3x1 5 45 Valve Set 46 O ring 9 5x1 9 47 O ring 10 3x1 9 48 Trigger Val...

Страница 19: ...35 Screw M5 12 36 Bushing 37 Safety Nosepiece 38 Washer 39 Depth Adjustment Screw M5 10 40 Rubber Cover 40a Cover Clip 41 Spring Pin 42 Safe Guide 43 O ring 18 4x2 4 44 O ring 20 3x1 5 45 Valve Set 46...

Страница 20: ...so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take...

Отзывы: