CentralPneumatic 68018 Скачать руководство пользователя страница 12

Page 12

For technical questions, please call 1-800-444-3353.

SKU 68018 

        

4.  To fire, open the shut-off valve, place 

the Safety against the workpiece.  The 

Stapler should not fire if the nose is not 

depressed.  Once depressed, gently and 

briefly squeeze the Trigger once.  

Do not 

fire repeatedly.

  

Staples could bounce 

off of one another, damaging the work 

piece or causing PERSONAL INJURY

.

5.  Adjust position of the Air Deflector (3) to 

direct exhaust away from yourself.

6.  If the tool requires more force to 

accomplish the task, verify that the 

tool receives sufficient, unobstructed 

airflow (CFM) and increase the pressure 

(PSI) output of the regulator up to the 

maximum air pressure rating of this tool. 

CAUTION!  TO PREVENT TOOL AND 

ACCESSORY FAILURE, RESULTING 

IN INJURY: Do not exceed the tool’s 

maximum air pressure rating.

 If the 

tool still does not have sufficient force at 

maximum pressure and sufficient airflow, 

then a larger tool may be required.

7. 

After use, to prevent accidents:

a. 

Release the Trigger.

b. 

Detach the air supply.

c. 

Attempt to fire the Tool into a piece 

of scrap wood to ensure that it is 

disconnected and is incapable of 

firing any fasteners.

d. 

Release the Trigger again.

e. 

Clean external surfaces with clean, 

dry cloth.

f. 

Store indoors out of children’s reach. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 68018

Страница 1: ...ight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams wit...

Страница 2: ...ious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to p...

Страница 3: ...othes jewelry or long hair increases the risk of injury to persons as a result of being caught in moving parts c Avoid unintentional starting Be sure the trigger is released before connecting to the a...

Страница 4: ...e tool s operation If damaged have the tool serviced before using Many accidents are caused by poorly maintained tools There is a risk of bursting if the tool is damaged h Use only accessories that ar...

Страница 5: ...forming any maintenance or repair c Clearing a jam d Moving the tool to a new location 13 Do not make any modifications to tool 14 Refer to the tool maintenance instructions for detailed information o...

Страница 6: ...that may occur It must be understood by operator that common sense and caution are factors which cannot be built into this product but must be supplied by operator Vibration Precautions This tool vibr...

Страница 7: ...a protective plug covering the air inlet Remove this plug before set up Air Supply TO PREVENT EXPLOSION Use only clean dry regulated compressed air to power this tool Do not use oxygen carbon dioxide...

Страница 8: ...r Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler and Plug Provides each connections F Leader Hose optional Increases coupler life G Air Cleaner Dryer optional Pr...

Страница 9: ...ll Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of use H Filter Prevents dirt and condensation from damaging tool or work piece I Air Cleaner Dryer...

Страница 10: ...th work pieces that have a thickness of less than 1 3 4 9 Inspect the air connections for leaks Repair any leaks found 10 If tool will not be used at this time turn off and detach air supply safely di...

Страница 11: ...eeze the Trigger The tool must cycle fire once only Release the trigger and squeeze it again The tool must cycle fire once only With the Trigger held carefully lift the nailer and press it against the...

Страница 12: ...tool receives sufficient unobstructed airflow CFM and increase the pressure PSI output of the regulator up to the maximum air pressure rating of this tool CAUTION TO PREVENT TOOL AND ACCESSORY FAILURE...

Страница 13: ...highly flammable causing an explosion Note These procedures are in addition to the regular checks and maintenance explained as part of the regular operation of the air operated tool Daily Air Supply M...

Страница 14: ...me out all the way back Use a screwdriver to release the jammed fastener by probing the openings in the Guide 8 Pull out the jammed fastener and the remainder of the fastener strip that is still in th...

Страница 15: ...s used 4 Magazine dirty or not lubricated properly 5 Insufficient air flow 1 Clear jammed fastener according to Clearing Jams instructions 2 Fill with correct fasteners 3 Empty then fill with correct...

Страница 16: ...51 Nail Guide Frame 1 52 Front Position Tab 1 53 Guiding Tab 1 54 Guiding Stem 2 55 Pusher Spring 2 56 Rear Position Tab 1 57 Hex Bolt M4x7 3 58 Spacing Tab 1 59 Pin 3x18 1 60 Pin 3x22 2 61 Position S...

Страница 17: ...purchase instead Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23...

Страница 18: ...tal or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHAN...

Отзывы: