Centralion MaxPower 1000 Скачать руководство пользователя страница 3

Safety – CAUTION! 

 

z

  This product is specially designed for PCs and it is not recommended 

for use in any life-supporting system and other specific important 
equipment. 

z

  This equipment can be operated by any individual with no previous 

training. 

z

  Do not plug household appliances such as hair dryers to UPS 

receptacles.

 

z

  This unit intended for installation in a controlled environment 

(temperature controlled, indoor area free of conductive contaminants). 
Avoid installing the UPS in locations where there is standing or 
running water, or excessive humidity.

 

z

  CAUTION: Risk of electric shock, do not remove cover. No user 

serviceable parts inside. Refer servicing to qualified service 
personnel. 

z

  The utility power outlet shall be near the equipment and easily 

accessible. To isolate UPS from AC input, remove the plug from the 
utility power outlet.

 

z

  If UPS is to be stored for a long time, it is recommended to recharge 

the batteries (by connecting the utility power to UPS, switch “ON”), 
once a month for 24 hours to avoid a full battery discharge. 

z

  Please do not use the UPS in excess of the rated load capacity. 

z

  The UPS contains one/two large-capacity batteries. So the shell shall 

not be opened, otherwise such dangers as electric shock will be 
caused. If any internal overhaul or replacement of the battery is 
required, please contact the distributor. 

z

  The internal short circuiting of the UPS will lead to dangers such as 

electric shock or fire, therefore, no water containers (such as a water 
glass) shall be placed on the top of the UPS so as to avoid such 
dangers as electric shock. 

z

  Do not dispose of battery or batteries in a fire.  The battery may 

explode. 

z

  Do not open or mutilate the battery or batteries.  Released 

electrolyte is harmful to the skin and eyes.    It may be toxic. 

z

 

Φ

  on the rating label stands for phase symbol. 

z

  A battery can present a risk of electrical shock and high short circuit 

current. The following precautions should be observed when working 
on batteries : 

1)  Remove watches, rings, or other metal objects from the hand. 
2)  Use tools with insulated handles. 

Содержание MaxPower 1000

Страница 1: ...USER S MANUAL MaxPower 1000 UPS Uninterruptible Power System 28 2MAXPO0019 ...

Страница 2: ...RTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for the model MaxPower 1000 that should be followed during installation and maintenance of the UPS and batteries ...

Страница 3: ...ecting the utility power to UPS switch ON once a month for 24 hours to avoid a full battery discharge z Please do not use the UPS in excess of the rated load capacity z The UPS contains one two large capacity batteries So the shell shall not be opened otherwise such dangers as electric shock will be caused If any internal overhaul or replacement of the battery is required please contact the distri...

Страница 4: ...sible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary z The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible z In case smoke is found coming out from the device please cut off the power supply quickly and cont...

Страница 5: ...el Power Switch 1 UPS status Indicator AC Mode Green lighting Battery Mode Green flashing 3 Fault LED Red flashing Back Panel 1 Output receptacles 2 Fuse 3 AC Input with AC fuse 4 AC Input 5 Modem Phone Line Surge Protection Option ...

Страница 6: ... during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 10 hours with no load no electrical devices such as computers monitors etc connected 3 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from exce...

Страница 7: ...ntinuously for 1 second and the UPS turns into its normal state the green light is on and the beeper is off after it performs a self diagnosis the beeper and the red and green indicator lights are on for several seconds At this time user may turn on the PC and other loads Press the switch of the UPS continuously for 1 second to turn off the UPS Note 1 For the convenience of maintenance please turn...

Страница 8: ...oad of the UPS 1 Remove some non critical load 2 Battery voltage is too low 2 Charge battery 8 hours or more When power failure backup time is short 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery 1 Fuse is blown 1 Replace the same type of fuse Mains normal but LED is flashing 2 Power cord is loose 2 Reconnect ...

Страница 9: ...ery Mode Green LED flashing every second Fault Red LED lighting Battery weak Vbat 24V at AC Mode Red LED flashing every 2 seconds for 30 seconds Battery Fault at AC Mode Red LED flashing three times every 2 seconds INDICATOR Overload Red LED flashing twice every second Battery Mode Sounding every 4 seconds Low Battery at Battery Mode Sounding every second Fault Continuously sounding Battery weak V...

Отзывы: