Service and Installation Manual
7
9
TROUBLE SHOOTING
Fault
Probable Cause
Action
Fuse blown or circuit breaker tripped
Replace fuse or reset circuit breaker.
Power cord unplugged
Plug in power cord
Compressor is Not Running
Thermostat set too high
Set thermostat to lower temperature
Thermostat is set too high
Set thermostat to lower temperature.
Airflow is blocked
Re-arrange products to allow for proper
air flow. Make sure there is at least
four inches of clearance from the fan
Low refrigerant levels
Contact a service technician to check
refrigerant levels
Cabinet Temperature is too Warm
Door is slightly ajar
Make sure door is completely closed.
Poor switch connection
Turn off light switch and turn it back on.
Bulb is not connected
Make sure the bulb is correctly inserted
in the socket.
Interior Light is Not Working
Bulb has burned out
Replace the bulb
Condensation is Collecting on the
Cabinet and/or Floor
Gasket is not sealing properly
Clean, repair, or replace the gasket as
necessary