CENTRAL RESTAURANT PRODUCTS 69K-102 Скачать руководство пользователя страница 4

Service and Installation Manual

 

 

OPERATION                                                                                                                                               

 

Do not throw items into the storage area. Failure to heed these recommendations could result in damage to 

the interior of the cabinet.

 

 
 

Refrigerated cycle 

Refrigerators:

 During the refrigeration cycle, the evaporator fans wilt run continuously even when one or 

more doors are open. The door switch will activate the lights when opened. 

1.

 

Every  6  hours,  the  unit  will  turn  off  and  to  allow  the  evaporator  coil  to  defrost.    The  controller  now 
displays the defrost symbol. When the coil temperature reaches 41°F or after 20 minutes of defrost, the 
unit will turn on again. 

2.

 

Anti-condensation heaters on door frames work in conjunction with the compressor. 

3.

 

The factory setting for the temperature range is 34°F to 38° F. 

On/Off Switch:   

An on/off switch is located on the front of 

the panel. When

 the unit is on, the switch will glow green. 

 
SOLID-STATE THERMOSTAT DESCRIPTIONS 

1.    FRONT PANEL COMMANDS                                                                                                                                                                                                         

 
 
 
 
 
 
 
 
 
 

To display target set point; in programming mode it selects a parameter or confirms an operation. 

To start a manual defrost 

To view the latest alarm occurrence; in programming mode it browses the parameter                       

codes or increases the display value 

To view the latest alarm occurrence; in programming mode it browses the parameter                   

codes or decreases the display value 

KEY COMBINATION 

To lock & unlock the keyboard 

To enter in programming mode 

To return to the room temperature display 

 
1.1 Function of LEDS 

 
 
 
 
 

 
 
 

Содержание 69K-102

Страница 1: ...Care Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS ...

Страница 2: ...ese instructions apply to all coolers Installations of equipment may not exactly correspond to your model INSTALLATION Make sure that the cooler is not damaged on arrival Your supplier must be notified of any transport damage within 24 hours of delivery The cooler should be placed in a warm dry room with suitable ventilation Place the cooler in such a way as to allow the free circulation of air ar...

Страница 3: ... be placed in sunlight or closed to a heat radiating surface If your cooler is fitted with a lock the key should be kept out of the reach of children If your new cooler is to replace an older one which is not in use any more you should remove the lock mechanism on the old one before disposing it STORAGE OFF FOOD STUFFS The cooler is only designed as a conserver and is the not suited to cold freeze...

Страница 4: ...i condensation heaters on door frames work in conjunction with the compressor 3 The factory setting for the temperature range is 34 F to 38 F On Off Switch An on off switch is located on the front of the panel When the unit is on the switch will glow green SOLID STATE THERMOSTAT DESCRIPTIONS 1 FRONT PANELCOMMANDS To display target set point in programming mode it selects a parameter or confirms an...

Страница 5: ...FFROST Hold the key for more than 2 seconds and the manual defrost will start 2 4 HOW TO LOCK THE KEYBOARD 1 Hold the and keys for more than 3s 2 The POF message will be displayed and the keyboard will be locked At this point it will be possible only to see the set point or the MAX or Min temperature stored 3 If a key is pressed more than 3s the POF message will be displayed 2 5 HOW TO UNLOCK THE ...

Страница 6: ...orking please call service personnel Inform them the nature of the problem the type of cooler serial number and item number provided on the nameplate at the back of the cabinet Do not open the cabinet as every opening hastens the thawing point As s rule the goods will not suffer damage at the first 12 hours If more time passes the goods must be moved to another cooler DISPOSAL When a worn out cool...

Страница 7: ...Service and Installation Manual 7 WIRING DIAGRAM MODEL 69K 100 69K 101 MODEL 69K 102 ...

Страница 8: ...Service and Installation Manual 8 WIRING DIAGRAM MODEL 69K 100 69K 101 ...

Страница 9: ...Service and Installation Manual 9 WIRING DIAGRAM MODEL 69K 102 ...

Отзывы: