Central Pneumatic 97525 Скачать руководство пользователя страница 4

SKU 

 

97525 

         

Page 

4

For technical questions, please call 1-800-444-3353.

heating up. Otherwise, the extension cord could melt and catch fire, or cause electrical 

damage to the tool. Check your air compressor’s manual for the appropriate size cord.  

It is also possible that the use of an extension cord may cause your circuit breaker to 

trip or your panel fuse to break.  If this happens, either use the compressor without an 

extension cord or find a larger amperage circuit to use.

19. 

Maintenance

.  The maintenance outlined in the maintenance section should be 

performed regularly.  For your safety, this product should be serviced or repaired 

regularly only by a qualified technician.

20. 

Compressed air only

.  Never use combustible gas as a power source.

21. 

Do not load nails with the trigger or safety depressed.

  Unintentional 

firing may occur.  Do not load nails when the air hose is connected to the 

tool.  Always assume that the tool contains fasteners.

22. 

Disconnect air supply before loading Nailer

.  Before reloading (or making any 

adjustments to) the Nailer make sure that the compressed air is disconnected.

23. 

Fire fasteners into an appropriate work surface only

.  Do not attempt to fire 

fasteners into surfaces too hard to penetrate.  Do not drive fasteners on top of other 

fasteners, or at too steep of an angle.  Fasteners can ricochet causing personal injury.  

Never fire the Nailer into the air, or point it toward yourself or another person.  Always 

wear ANSI approved safety goggles during use, maintenance, and reloading.

24. 

Do not fire fasteners too close to the edge of a workpiece

.  They may split the 

workpiece and fly free, causing personal injury.

25. 

Take caution as some woods contain preservatives such as copper chromium 

arsenate (CCA) which can be toxic

. When stapling or nailing these materials extra 

care should be taken to avoid inhalation and minimize skin contact.

26.  Some dust created by power sanding, sawing, grinding, drilling, and other construction 

activities, contain chemicals known [to the State of California] to cause cancer, birth 

defects or other reproductive harm.  Some examples of these chemicals are: 

• Lead from lead-based paints 

• Crystalline silica from bricks and cement or other masonry products 

• Arsenic and chromium from chemically treated lumber 

(California Health & Safety Code § 25249.5, et seq. )

27. 

Stay within air pressure capacity

.

  

Never operate the Nailer above 100 PSI.

28. 

Hold tool away from head and body

.  During operation the Nailer may kick back 

causing injury.

29. 

Transport Nailer safely

.  Always disconnect air supply when moving the tool in the 

workplace.  Carry the tool by the handle and avoid contact with the trigger.

30.  The warnings, cautions, and instructions discussed in this instruction manual cannot 

cover all possible conditions and situations that may occur. It must be understood by 

the operator that common sense and caution are factors which cannot be built into this 

product, but must be supplied by the operator.

Содержание 97525

Страница 1: ...ts reserved No portion of this manual or any artwork con tained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual ma...

Страница 2: ...ng this tool 1 Keep work area clean Cluttered areas invite injuries 2 Observe work area conditions Do not use machines or power tools in damp or wet locations Do not expose to rain Keep work area well...

Страница 3: ...your finger on the trigger whether it is attached to an air source or not Do not point the tool towards yourself or anyone whether it contains fasteners or not 13 Stay alert Watch what you are doing u...

Страница 4: ...into the air or point it toward yourself or another person Always wear ANSI approved safety goggles during use maintenance and reloading 24 Do not fire fasteners too close to the edge of a workpiece...

Страница 5: ...ice you should incorporate an oiler regulator and inline filter as shown in the diagram above Hoses couplers oilers regulators and filters are all available at Harbor Freight Tools 1 You will need to...

Страница 6: ...by a qualified service technician Operation Testing The Single Sequential Safety Trip Mechanism continued Loading Nails or Staples ALWAYS WEAR ANSI APPROVED IMPACT SAFETY GOGGLES WHEN RELOADING OR DO...

Страница 7: ...gure 3 4 Carefully slide the Driver Cover 50 off around the Safety 42 Note the position of the tab on the Driver Cover 50 Remove the jammed fastener pliers may be necessary to remove a stuck fastener...

Страница 8: ...t 9 leaking 1 Replace Bumper 85 or Pusher Spring 2 Clean channels in Driver Guide 52 3 Check hose and compressor fittings 4 Replace or lubricate O Rings 5 Replace O Rings 6 Replace Gasket 9 Fasteners...

Страница 9: ...THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO T...

Страница 10: ...7525 Page 10 For technical questions please call 1 800 444 3353 Assembly Drawing NOTE Some parts are listed and shown for illustration purposes only and are not available individually as replacement p...

Страница 11: ...tal or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTH ER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MER CH...

Отзывы: