Page 5
For technical questions, please call 1-800-444-3353.
94801 / 65594 95
Maintenance
1. Regularly drain water condensation
from of Tank, which can lead to internal
corrosion and damage to the tank.
To drain, hold Tank upside down and
remove the Bypass Valve Spring (2).
2. Due to internal corrosion, do not use the
tank beyond the destroy date stamped
into the leg of the Tank (1). Safely
disable the tank as follows:
a. Depressurize air tank completely, by
holding the Bypass Valve Spring open.
WARNING!
Failure to properly depressurize
the tank before proceeding may result in
serious personal injury.
b. Remove the pressure gauge and hose.
c. Deliver the tank to a pressure tank
disposal service, if available.
d. If a pressure tank disposal service is not
available, place the tank in a secure,
stable working location and drill at
least two 1/2” (or larger) holes through
the side of the tank. Then, deliver to
appropriate recycling center.
STORING THE AIR TANK
1. Turn the round On/Off Wheel (5)
clockwise to the Off position. This will
keep air from leaking out of Air Hose.
2. Store in a dry, dust-free location away
from children and any flammable
materials.
3. To remove all air from the Air Tank, pull
the Ring (13) until the Gauge indicates
zero and the air flow stops.
I
f
there
Is
any
questIon
about
a
condItIon
beIng
safe
or
unsafe
,
do
not
operate
the
tool
.
Record Serial Number Here:
Note:
If product has no serial number, record month and year of purchase instead.
Note:
Some parts are listed and shown for illustration purposes only, and are not available
individually as replacement parts.
Maintenance