Central Pneumatic 61693 Скачать руководство пользователя страница 3

Page 3

For technical questions, please call 1-888-866-5797.

ITEM 61693 

        

SAFET

y

SETU

p

Op

ERA

TION

M

AINTENAN

c

E

IMpORTANT SAFETy INFORMATION

General Safety Warnings

  WARNING Read all safety warnings and instructions.   

Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.   

Save all warnings and instructions for future reference.

The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible 

conditions and situations that may occur.  It must be understood by the operator that common sense 

and caution are factors which cannot be built into this product, but must be supplied by the operator.

1. 

Work area safety

a. 

Keep work area clean and well lit.

  

Cluttered or dark areas invite accidents.

b. 

Do not operate the compressor in explosive 

atmospheres, such as in the presence 

of flammable liquids, gases or dust.

  

Compressor motors produce sparks 

which may ignite the dust or fumes.

c. 

Keep children and bystanders away 

from an operating compressor.

2. 

Electrical safety

a. 

compressor plugs must match the outlet.  

Never modify the plug in any way.  

Do not use any adapter plugs with grounded 

compressors.

  Standard plugs and matching 

outlets will reduce risk of electric shock.

b. 

Do not expose compressor to rain or wet 

conditions.

  Water entering a compressor 

will increase the risk of electric shock.

c. 

Do not abuse the cord.  Never use the 

cord for unplugging the compressor.  

Keep cord away from heat, oil, sharp edges 

or moving parts.  

Damaged or entangled 

cords increase the risk of electric shock.

3. 

personal safety

a. 

Stay alert, watch what you are doing and 

use common sense when operating this 

compressor.  Do not use this compressor 

while you are tired or under the influence 

of drugs, alcohol or medication.

  A moment 

of inattention while operating a compressor 

may result in serious personal injury.

b. 

Use personal protective equipment.  

Always wear ANSI-approved eye 

protection during setup and use.

c. 

prevent unintentional starting.  Ensure the 

switch is in the off-position before connecting 

to power source or moving the compressor.

4. 

compressor use and care

a. 

Do not use the compressor if the switch 

does not turn it on and off.

  Any compressor 

that cannot be controlled with the switch 

is dangerous and must be repaired.

b. 

Disconnect the plug from the power source 

before making any adjustments, changing 

accessories, or storing the compressor.

  

Such preventive safety measures reduce the 

risk of starting the compressor accidentally.

c. 

Store an idle compressor out of the reach 

of children and do not allow persons 

unfamiliar with the compressor or these 

instructions to operate it.

  A compressor is 

dangerous in the hands of untrained users.

d. 

Maintain the compressor.  Keep the 

compressor clean for better and safer 

performance.  Follow instructions for 

lubricating and changing accessories.  

Keep dry, clean and free from oil and grease.  

check for misalignment or binding of moving 

parts, breakage of parts and any other 

condition that may affect the compressor’s 

operation.  If damaged, have the compressor 

repaired before use.

  Many accidents are 

caused by a poorly maintained compressor.

e. 

Use the compressor in accordance with 

these instructions, taking into account 

the working conditions and the work to 

be performed.

  Use of the compressor for 

operations different from those intended 

could result in a hazardous situation.

5. 

Service

a. 

Have your compressor serviced by a 

qualified repair person using only identical 

replacement parts.

  This will ensure that the 

safety of the compressor is maintained.

Содержание 61693

Страница 1: ...ce for future reference When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2013 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams wit...

Страница 2: ...symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a hazardous situation which if not avoided will result in death or serious injury Indicates a hazardous situation which if not avoided could result in death or serious injury Indicates a hazardous situation which if not avoided could resul...

Страница 3: ... use this compressor while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating a compressor may result in serious personal injury b Use personal protective equipment Always wear ANSI approved eye protection during setup and use c Prevent unintentional starting Ensure the switch is in the off position before connecting to power source or movin...

Страница 4: ...r is greater 15 USE OF AN EXTENSION CORD IS NOT RECOMMENDED If you choose to use an extension cord use the following guidelines Table A RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS 120 VOLT NAMEPLATE AMPERES at full load EXTENSION CORD LENGTH 25 50 100 150 0 6 18 16 16 14 6 1 10 18 16 Do not use 10 1 12 16 16 Do not use 12 1 16 14 12 Do not use a Make sure your extension cord is in good cond...

Страница 5: ... risk of electric shock The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding conductor to a live terminal 4 Check with a qualified electrician or service personnel if the grounding instructions are not completel...

Страница 6: ...t under subheadings therein before set up or use of this product TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION Turn the Power Switch OFF and unplug the Air Compressor from its electrical outlet before assembling or making any adjustments to the compressor Note For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manua...

Страница 7: ...ng Washer 78 Washer 77 Foot Pad 76 Washer 75 Nut 79 Nut 72 Tank 68 Figure C 2 Attach the Foot Pads 76 to the bottom of the Tank using the Bolts 74 Washers 75 77 Spring Washers 78 and Nuts 79 See Figure C 3 Slide the Handle 67 into the two fittings on the Tank and secure it in place with four Bolts 66 See Figure D Handle 67 Bolt 66 Tank Figure D 4 Thread the Air Filter 8 onto the side of the Cylind...

Страница 8: ... Plug Cold Weather Operation Premium quality 30 weight non detergent air compressor oil sold separately is recommended for use with this compressor Start compressor in heated area if outdoor temperatures drop below 32 F If this is not practical drain out the old pump oil and use SAE 10W Non detergent Air Compressor Oil in the pump crankcase instead whenever the compressor s temperature will fall b...

Страница 9: ... free movement while working Note An in line shutoff ball valve is an important safety device because it controls the air supply even if the air hose is ruptured The shutoff valve should be a ball valve because it can be closed quickly 2 Depending on the tool which you will be using with this compressor you may need to incorporate additional components such as an in line oiler a filter or a dryer ...

Страница 10: ...Air Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler and Plug Provides quick connection and release F Leader Hose optional Increases coupler life G Air Cleaner Dryer optional Prevents water vapor from damaging workpiece H Air Adjusting Valve optional Fo...

Страница 11: ...vibration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of use H Air Hose Connects air to tool I Filter Prevents dirt and condensation from damaging tool or workpiece J Regulator Adjusts air pressure to tool K Lubricator optional For air tool lubrication L Co...

Страница 12: ...sure cut out Look for air bubbles If air bubbles are present at connections tighten connections Do not use the Air Compressor unless all connections are air tight the extra air leaking out will cause the Compressor to operate too often increasing wear Note As long as the Power Switch is set to ON the Air Compressor s operation is automatic controlled by an internal pressure switch The Air Compress...

Страница 13: ...before reaching its normal cutoff pressure a Shut off all tools b Wait until the Air Compressor cools down about 10 minutes c If the unit does not start up again on its own press the Reset Button to start the compressor See Figure I d Resume operation Reset Button Figure I 2 Possible causes of repeated automatic shut off of the Air Compressor are Using an extension cord that is too long or too sma...

Страница 14: ...es of the compressor with a clean cloth 3 WARNING If the supply cord of this compressor is damaged it must be replaced only by a qualified service technician Maintenance Schedule Following are general guidelines for maintenance checks of the Air Compressor Note The environment in which the compressor is used and the frequency of use can affect how often you will need to check the Air Compressor co...

Страница 15: ... Compressor with new SAE 30W non detergent Air Compressor Oil to the FULL level on the Oil Sight Glass 5 6 oz 6 Replace and tighten the Oil Breather Plug 7 Discard the old oil according to local state and federal regulations Draining Moisture from the Tank The Drain Valve is located on the bottom of the Tank It must be used daily to release all trapped air and moisture from the Tank This will elim...

Страница 16: ...rankcase oil overfilled or oil too thick 3 Working environment too cold 4 Safety valve leaking 5 Loose fittings 1 Check that circuit matches compressor requirements 2 Drain oil and refill to proper level with recommended oil 3 Move compressor to a warmer location Check that recommended oil is in crankcase 4 Listen for air leaking from valve If leaking replace with identical valve with same rating ...

Страница 17: ...on for air leaks and tighten as needed Do not overtighten 4 Reposition unit on a level surface Moisture in discharge air Too much moisture in air Install inline air filter dryer and or relocate to less humid environment Oil in discharge air 1 Crankcase oil too thin or crankcase overfilled with oil 2 Crankcase vents clogged 1 Drain oil and refill to proper level with recommended oil 2 Clean Crankca...

Страница 18: ...5 Zip Tie 2 26 Capacitor 1 27 Adhesive Sticker 1 28 Bolt M8 x 20 1 29 Capacitor Bracket 1 30 Crankcase Cover Gasket 1 31 Oil Breather Plug 1 32 Crankcase Cover 1 33 Screw M6 x 20 4 34 Oil Sight Glass 1 35 Oil Sight Glass Gasket 1 36 Oil Drain Plug M6 x 10 1 37 O Ring 1 38 Crankcase 1 39 Screw M6 x 16 10 40 Overload Protector 1 Part Description Qty 41 Oil Seal 1 42 Bearing 1 43 Rotator 1 44 Bearing...

Страница 19: ...Page 19 For technical questions please call 1 888 866 5797 ITEM 61693 Safety Setup Operation Maintenance Assembly Diagram ...

Страница 20: ...so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If o...

Отзывы: