Central Hydraulics 92038 Скачать руководство пользователя страница 4

SKU 92038     For technical questions, please call 1-800-444-3353.         Page 4

14.

Maintain Pumps with care.  Keep them clean.  Do not use a damaged Pump.
Tag damaged Pumps “Do not use” until repaired.

15.

Check for, breakage of parts and any other condition that may affect the
Pump’s operation.  If damaged, have the Pump serviced before using.
Many accidents are caused by poorly maintained Pumps.

16.

Use only accessories that are recommended by the manufacturer for your
model.  
Accessories that may be suitable for one Pump may become hazardous
when used on another Pump.

SERVICE

17.

Pump service must be performed only by qualified repair personnel.
Service or maintenance performed by unqualified personnel could result in a risk
of injury.

18.

When servicing a Pump, use only identical replacement parts.  Follow
instructions in the 

“Inspection, Maintenance, And Cleaning” section of this

manual.  Use of unauthorized parts or failure to follow maintenance instructions
may create a risk of electric shock or injury.

SPECIFIC SAFETY RULES

1.

Maintain labels and nameplates on the Pump.  These carry important
information.  If unreadable or missing, contact Harbor Freight Tools for a
replacement.

2.

Always wear ANSI approved safety impact eye goggles and heavy work
gloves when using the Pump.   
Using personal safety devices reduce the risk
for injury. Safety impact eye goggles and heavy work gloves are available from
Harbor Freight Tools.

3.

Maintain a safe working environment.  Keep the work area well lit.  Make sure
there is adequate surrounding workspace.  Always keep the work area free of
obstructions, grease, oil, trash, and other debris.  Do not use an Electric Pump in
areas near flammable chemicals, dusts, and vapors.  Do not use this product in a
damp or wet location.

4.

Avoid unintentional starting.  Make sure you are prepared to begin work
before turning on the Pump.

5.

All hydraulic hoses and hydraulic systems to be used with this pump must
be rated at a working pressure of at least 2200 PSI.

6.

Never leave the Pump unattended when it is plugged into an electrical
outlet.  
 Turn off the Pump and unplug it from its electrical outlet before leaving.

Содержание 92038

Страница 1: ...All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions and replacement parts please call 1 800 444 3353 TO PREVENT SERIOUS INJURY READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE 220 VOLT HYDRAULIC ELECTRIC PUMP R REV 12 04 ...

Страница 2: ...G READ AND UNDERSTAND ALL INSTRUCTIONS Failure to follow all instructions listed below may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS WORK AREA 1 Keep your work area clean and well lit 2 Do not operate electric pumps in explosive atmospheres such as in the presence of flammable liquids gases or dust Pumps may create sparks and arcing which may ignite the dust or fu...

Страница 3: ...n sense when operating a the Pump Do not use the Pump while tired or under the influence of drugs alcohol or medication A moment of inattention while operating this Pump may result in serious personal injury 9 Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving pa...

Страница 4: ...isk of electric shock or injury SPECIFIC SAFETY RULES 1 Maintain labels and nameplates on the Pump These carry important information If unreadable or missing contact Harbor Freight Tools for a replacement 2 Always wear ANSI approved safety impact eye goggles and heavy work gloves when using the Pump Using personal safety devices reduce the risk for injury Safety impact eye goggles and heavy work g...

Страница 5: ...le with pacemakers should consult their physician s before using this product Electromagnetic fields in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker GROUNDING The Power Cord requires the attachment of a 220 volt grounded 3 Prong Plug not included For safety purposes only a qualified certified electrician should attach a Plug to the Power Cord Never m...

Страница 6: ...re than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Figure C EXTENSION CORDS 6 If you are using an extension cord outdoors make sure it is marked with the suffix W A W in Canada to indicate it is acceptable for outdoor use 7 Make sure your extension cord is properly wired and in good electrical condition Always replace a damaged extension cord...

Страница 7: ... The Power Cord requires the attachment of a 220 volt grounded 3 Prong Plug not included For safety purposes only a qualified certified electrician should attach a Plug to the Power Cord Never modify the Plug in any way To comply with the National Electric Code and to provide additional protection from the risk of electrical shock this product should only be connected to a 220 volt electrical outl...

Страница 8: ... ends of a NPT 3 8 male connector not included Tighten one end of the male connector not included into the female connection see Assembly Drawing on page 12 6 Securely attach the other end of the connector to the hydraulic system Operation 1 Plug the Pump into an approved 220 Volt outlet 2 Press down on the Pressure Release Handle 3 to completely release hydraulic pressure 3 To pressurize the syst...

Страница 9: ... the general condition of the Pump Check for loose screws misalignment or binding of moving parts cracked or broken parts leaking hydraulic fluid damaged electrical wiring and any other condition that may affect its safe operation If abnormal noise or vibration occurs have the problem corrected by a qualified technician before further use Do not use damaged equipment 3 Wipe the Pump clean with a l...

Страница 10: ...THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION ORWARRANTY OF ANY KINDTOTHE BUYERTHAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATESTHAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED A...

Страница 11: ... please call 1 800 444 3353 Page 11 NOTE Some parts are listed and shown for illustration purposes only and are not avail able individually as replacement parts ASSEMBLY DIAGRAM Hydraulic Oil Fill Female Connection 3 8 NPT Lift Button ...

Отзывы: