Length
285 mm / 11
7
/
32
”
Depth
144 mm / 5
21
/
32
”
Height
134 mm / 5
9
/
32
”
Weight
1.65 kg
Capacity
1.7 litres
285mm / 11
7
/
32
”
134mm / 5
9
/
32
”
Max. flow (@ 0 m/ft)
300 L/hr
Max. rec. head
5m
Sound level @ 1m
49 dB(A)
Pump Power supply
230 VAC, 0.8 A, 50Hz
Non Continuous
5mins on, 5mins off
Class
I Appliance
Max. AC unit output
200kW - 682,000 Btu/h
Max. water temp
60º C / 140º F
Inlets/Outlets
Ø21mm to Ø27mm /
6mm (1/4”) & 10mm (3/8”)
IP Protection
IP24
Safety switch
3 A Normally closed
Thermal protection
✓
SPECIFICATIONS
1 This pump has been designed for the removal of pH +2.2
condensate water ONLY.
2 Ensure 1 Amp fuse is installed.
3 Following installation of the pump the tank should
be filled with water until the motor runs. Pipes and
connections should be checked for leaks and discharge of
water checked. The operation of the safety switch should
also be checked.
4 Do not use these pumps in oily or very dusty environments.
5 Install hose and wiring in accordance with manufacturers
instructions. Do not use discharge hose larger than
3/8”/10mm I.D.
6 Inspect pump, clean floats, and tank regularly checking for
correct operation.
7 Do not use any unapproved cleaning chemicals this pump.
Operating the pump when unapproved or poorly mixed
cleaning chemicals are present will result in permanent
damage to pump and void warranty. Ensure all cleaning
chemicals are thoroughly flushed out of the pump with
clean water.
8 After initial installation and/or maintenance, do not leave
site until pump has been tested for correct operation.
9 When commissioning the pump, please check for debris
in the pump – remove any material that might block the
drain line or drain into the boiler pump.
10 NOISE: All Center Brand pumps operate quietly, however
under certain conditions where an extremely low ambient
noise level is present, the sound of their intermittent
operation may still be perceived as noisy. Always confirm
acceptable noise level before installing any condensate
pump in a bedroom or other noise sensitive area.
Correct sequence of operation:
1 Boiler drains water which flows into pump’s tank.
2 When the water lifts the float to the correct level the
pump will activate.
Fault Conditions:
In the unlikely event of a pump failure check the following:
1 Power supply: Ensure power is supplied to pump.
2 Hi level safety switch: Ensure hi level safety switch has not
operated. If it has, check pump performance is suited to
incoming flow rate.
3 Pump is loud: Pump fixing may be loose or the connected
cables and hoses may be vibrating against a hard surface.
4 Outlet Pipe: Check pipe, and outlet barb are not blocked
with debris or kinked.
AC max. unit sizing chart
Head / m
L / hr
kW
0
300
400
1
215
287
2
159
212
3
106
141
4
65
87
5
36
48
5.4
0
0
LITRES PER HOUR
METRES HEAD
6
5
4
3
2
1
0
100
Max. rec. head 5m
200
300
400
500
600
6mm (¼”)
Information correct at the time of going to press.
PERFORMANCE
IMPORTANT
2
Boiler Condensate Pump - Installation Guide