Boiler Condensate Pump - Installation Guide
This pump is designed to collect condensate water from
large domestic and commercial gas & oil fired condensing
boilers and discharge it up to recommended maximum
5 metres head. The internal safety float is a low current
switch to stop the boiler system in the event of pump
failure. The pump is operated from an internal float switch.
ELECTRICAL WARNING!
Isolate before working on this unit.
Service Guide:
Flush the pump through with anti-bacterial wash every six
months to avoid sludge build-up in the pump housing.
NB The contractors should satisfy themselves that any
chemicals used are compatible with the working of the pump.
IMPORTANT:
Pump should be filled with water until motor runs, check for
leaks and proper discharge of water.
1
IN THE BOX
Information correct at the time of going to press.
10mm I.D. x 6m
Pipe Adaptor
Boiler installation
5m
Ensure that there are no kinks or trapped parts in the piping,
which must have an inside diameter of 6mm. Fix the pipe with
cable ties to the pump outlet.
IMPORTANT:
The pre-wired safety switch MUST ALWAYS be utilised.
667888