MINI CLAMP METER Instruction Manual
2
II. Specification
General Specification:
Digital Display:
3 1/2 digits LCD display with maximum reading 1999
Over Load:
When the indication is larger than the 1999 counts, the LCD
will show 1000 with blinking 1
Sample Rate:
2 times/sec
Low Power Indication:
When the battery is under the proper operation range,
symbol will appear on the LCD display.
Power Source:
UM-4 or AAA 1.5V battery x 2.
Clamp opening size:
25mm
Dimension
(L x W x H)
:
187x50x29mm, 7.36x1.97x1.14 inch
Weight:
210g( include battery)
Accessory:
Instruction Manual, Carrying Case, Test lead, Battery
1.5Vx2
Battery Life:
1000
hr approx. (alkaline battery)
Electrical Specification:
The accuracy specification is defined as
±
( …%reading
+
…count )
At 23
±
5
℃
,
≦
80 %RH
ACA (Autorange)
Range
Resolution
Accuracy ( 50Hz~60Hz)
Overload Protection
200A 0.1A
600A 1A
2%+5 660Arms