background image

300V  CAT III

COM

600V

0 - 200

0 - 600 V

0 - 600 A

600V  CAT II

OFF

V

A

V

A

300V  CAT III 

600V  CAT II 

HOLD

600A

                       

             

 

 
 

                                   

 

 

 
 
 
 

           

                       

 

 

 

 

  

 

MINI CLAMP METER 

Содержание 221

Страница 1: ...300V CAT III COM 600V 0 200 0 600 V 0 600 A 600V CAT II OFF V A V A 300V CAT III 600V CAT II HOLD 600A MINI CLAMP METER ...

Страница 2: ...bols 1 II Specification 2 General Specification 2 Electrical Specification 2 III Instrument Familiarization 3 Symbol Definition 3 IV Measuring Instruction 5 4 1 ACA measurement 5 4 2 ACV measurement 6 4 3 Resistance measurement 7 4 4 Continuity Test 8 V Battery Changing 9 VI Maintenance 9 ...

Страница 3: ...his manual Exercise extreme caution when measuring live system with voltage greater than 60V DC or 30V AC Keep the fingers after the protection ring when measuring through the test lead Change the battery when the symbol appears to avoid incorrect data Environmental Conditions Altitude up to 2000 meters Operating temperature 0 C 40 C 80 RH non condensing Storage temperature 10 C 60 C 70 RH battery...

Страница 4: ...the proper operation range symbol will appear on the LCD display Power Source UM 4 or AAA 1 5V battery x 2 Clamp opening size 25mm Dimension L x W x H 187x50x29mm 7 36x1 97x1 14 inch Weight 210g include battery Accessory Instruction Manual Carrying Case Test lead Battery 1 5Vx2 Battery Life 1000 hr approx alkaline battery Electrical Specification The accuracy specification is defined as reading co...

Страница 5: ...Range Resolution Accuracy MAX Test Voltage Overload Protection 200Ω 0 1Ω 1 9 3 1 6VDC 500Vrms Continuity Range Active Region MAX Test Voltage Overload Protection 100 Ohm 1 6VDC 500Vrms III Instrument Familiarization Symbol Definition Ohm Indicator Ampere Indicator Voltage Indicator Continuity Data Hold Low Battery Alternate Signal Digital Reading ...

Страница 6: ...V CAT III V V A 0 600 V 0 200 0 600 A A OFF HOLD 600V CAT II 300V CAT III 600A Instrument Familiarization Current Sensing Clamp Positive input terminal Safety protection ring Function select dial Clamp opening handle Data hold button LCD display COM input terminal ...

Страница 7: ...T II HOLD 600A IV Measuring Instruction 4 1 ACA measurement Switch the function selector to A range Open the clamp by pressing the jaw opening handle and insert the cable to be measured into the jaw Close the clamp and get the reading from the LCD panel Note Before this measurement disconnect the test lead with the meter for safety In some occasion that the reading is hard to read push the HOLD bu...

Страница 8: ...ct red test lead to terminal and black one to the COM terminal Measure the voltage by touch the test lead tips to the test circuit where the value of voltage is needed Read the result from the LCD panel 600V 600V CAT II 300V CAT III 0 600 V 0 200 0 600 A OFF 600V CAT II 300V CAT III COM V A V A HOLD 600A ...

Страница 9: ...M terminal Connect tip of the test leads to the points where the value of the resistance is needed Read the result from the LCD panel Note When take resistance value from a circuit system make sure the power is cut off and all capacitors need to be discharged COM A V 600V 300V CAT III 600V CAT II 0 600 A 0 200 0 600 V A V OFF HOLD 300V CAT III 600V CAT II 600A ...

Страница 10: ...witch the function selector to range Connect red test lead to terminal and black one to the COM terminal Connect tip of the test leads to the points where the conducting condition needed If the resistance is under 100Ω the beeper will sound continuously Beeper 600V 600V CAT II 300V CAT III 0 600 V 0 200 0 600 A OFF 600V CAT II 300V CAT III COM V A V A HOLD 600A ...

Страница 11: ...size batteries 3 Close the back cover and fasten the screw VI Maintenance CAUTION To avoid contamination or static damage do not touch the circuit board without proper static protection REMARK If the meter is not going to be used for a long time take out the battery and do not store the meter in high temperature or high humidity environment When make current measurement keep the cable at the cente...

Страница 12: ...CENTER TECHNOLOGY CORP 4 F NO 415 Jung Jeng Rd 238 Shu Lin Taipei Taiwan TEL 886 2 26763926 E Mail center centertek com FAX 886 2 26763925 http www centertek com 221 01 ...

Отзывы: