Assembly and operating instructions
CENTAX-TT
024T-00130…00460
M024-00001-EN
Rev. 6
CENTA Antriebe Kirschey GmbH
17 / 54
Measure the radial misalignment with a dial gauge (see Fig. 5-2).
Attach the dial gauge (D) to the adapter (3).
Set the sensor of the dial gauge (D) radially against the flywheel (B).
Turn the adapter (3) with the dial gauge (D) and the flywheel (B) slowly
by 360°.
Align the units (calculated deviation
≤∆K
R max
).
The permissible radial alignment tolerance
∆K
R max
can be found in the following
table.
Size
∆K
R max
[mm]
130 - 260
0.1
340 - 360
0.12
440 - 460
0.15
Table 5-2 Permissible radial alignment tolerance