OPERATING THE SAW 

 
We recommend that eye protection be worn, and normal safe   
working practices observed as per the Health and Safety at work 
act,  and the appropriate National and State Laws

.

 

The JSZ should be used in conjunction with the pipe clamp where 
possible. 
Connect the air supply, rest the blade on the material to be cut with 
the nosepiece firmly abutted to the work piece, with forward hand 
pressure, to prevent judder. Allow the Cengar Saw to cut under its 
own weight, with just a slight downward hand pressure to keep the 
teeth engaged in the cut. It is not necessary to put excessive 
downward pressure on the saw, this only accelerates blade wear, 
and prevents the saw from operating efficiently. Normal airline 
pressure of 5 to 6 Bar is required , any higher pressure only          
accelerates internal wear of the machine. 
 

USE IN HAZARDOUS AREAS

 

 
We strongly advise that the contact area of the blade on the work 
piece be quenched with coolant or water during cutting to dissipate 
any heat which may be created by the cutting process. 
            Anti-static  conductive  air  hose  must  be  used,  with  adequate 
earth bond continuity (resistance below 1 ohm), to ground any 
electrostatic charges. 
 

MAINTENANCE AND GENERAL HINTS 

 
Always ensure sufficient oil in the tool, especially when the saw is 
in constant use. 
 
The valve unit part no. 8308 is a vital component manufactured to 
close tolerances, and will not tolerate abusive treatment. Lubrication 
is essential. Any neglect will seriously affect performance of the 
saw, causing the saw to stall intermittently, or stop completely. 
 
Very little maintenance is required if the correct oil is used, but 
incorrect oil will soon breakdown into sludge, slowing down the 
action of the saw, necessitating its removal by use of Cengar M.S. 
Cleaner. It is imperative that the saw is re-oiled immediately after 
cleaning, with Cengar Green Oil. 

Содержание JSZ

Страница 1: ......

Страница 2: ...onformity with the following relevant EC legislation Machinery Directive 2006 42 EC Atex Directive 94 9 EC Based on the following Harmonised Standards EN13463 1 2009 And therefore complies with the essential requirements of those directives Additional Information ATEX Coding II 2G T5 Certificate No TRAC09ATEX21236X Technical File No CEEX 0803 Authorised Signature Date 15 12 09 Title of Signatory G...

Страница 3: ...tion 400 600 strokes per minute 57 mm 0 168m3 minute 5 6 Bar 5 5 Kgs 448 mm 141 mm 54 mm 1 38 m s2 80 5 db 89 9 db CE II 2G T5 X Cengar Air Saw Model JSZ We recommend normal safe working practices should be followed as per the Health and Safety at Work Act or the appropriate National and State Laws We recommend that eye protection be worn when using Cengar Saws ...

Страница 4: ...ich will slow and eventually stop the action of the saw See maintenance details INSTALLATION OF BLADES Before attempting to insert or change a blade ensure that the air supply is isolated by disconnecting the air line Loosen the retaining grub screws with the key provided insert blade through nosepiece so that the teeth are cutting on the pull stroke Locate the back screw in the hole in the end of...

Страница 5: ... IN HAZARDOUS AREAS We strongly advise that the contact area of the blade on the work piece be quenched with coolant or water during cutting to dissipate any heat which may be created by the cutting process Anti static conductive air hose must be used with adequate earth bond continuity resistance below 1 ohm to ground any electrostatic charges MAINTENANCE AND GENERAL HINTS Always ensure sufficien...

Страница 6: ...JSZ Exploded View ...

Страница 7: ... Oil Plug Seal 1 25 53034 Screws 4 8 8307F Filter 1 26 8310 Piston 2 9 8308 Valve Unit Complete 1 27 8310LS Piston Seal 2 10 8307 Gasket 2 28 8312 Ling to Pistons 1 11 8309Z Body 1 29 8318 Connecting Rod 1 12 8314 Speed Regulator 1 30 55516 Blade Grip Screws 2 13 5012 O Ring 2 31 51114 Pins to Piston 2 14 5006 O Ring 1 32 51114 Pin to Conn Rod 1 15 8315A Spring 1 33 0291 O Ring 1 16 8315 Clamp Sec...

Страница 8: ...ect saw to air supply REPLACEMENT OF PISTON SEALS 1 Each seal consists of two rings replacements must be fitted as follows 2 Place the elastic ring in the centre of the piston groove ensuring it is not twisted 3 Fit the Stiffer sealing ring on top of the elastic ring Use some green oil to ease its passage over the piston 4 Fit the pistons into the bores using a ring compressor with a coating of Ce...

Страница 9: ...at the weight of the machine applies the cutting force to the blade Fig 2 6 Start the machine locking on the trigger and gently bring the blade into contact with the work gradually release the weight of the machine and allow the cut to take place without extra force 7 If using a long blade for larger diameter pipes the bow guide supplied can be used to ensure a straight cut is achieved Once the bl...

Страница 10: ...ernal parts with anything other than a clean lint free cloth and M S Cleaner or Cengar Green oil 9 NEVER modify Cengar saws or use non Cengar parts this will invalidate ATEX approval and warranty ALWAYS 1 ALWAYS use Cengar green oil for best results Keeping the saw clean and well oiled will give excellent reliability and a long life 2 ALWAYS use Cengar Bi Metal Shatterproof blades for safety and b...

Страница 11: ...50 ml plastic bottles for all air tools GO 9109 As above in 5 litre container GO 9110 As above in 25 litre container M S Cleaner MS 9105 1 litre General purpose cleaning fluid for air tools MS 9125 50 ml In a dropper bottle Enough for 10 tools Always use plenty of Cengar green oil afterwards Pipe Clamp CP 1 Clamp to mount saw to sections Bow Guide CP 2 Bow Guide assembly to keep longer blades in l...

Страница 12: ...24 enquiries cengar com www cengar com SERVICE We offer a full factory repair and refurbishment service for Cengar Saws normally within 5 working days Quotations at no charge can be given before work is carried out DISTRIBUTOR ADDRESS Manual Document No MANJSZENG 01 Issue 06 Jan 10 ...

Отзывы: